Type BMT 60
System design Closed
Rated pressure 10 bar/1.0Mpa
Nominal capacity L.
<
0.25
Dimension (H x W x D) mm. 220 x 170 x 80
Weight (empty) kg. 1.4
Electrical connection 1/N/PE~220...230 V.
Power Regulating device 4 steps control (Off - Low - Med -High)
Rated power (kW) - Rated current (A) kW - A
220 V 6.0 - 27.3
230 V 6.6 - 28.7
Reccommended circuit breaker (A) 30
Reccommended cable size (Sqmm.) 6.0
Water connections (surface installation) G ½”
Handing over the unit
Explain to the user how the unitworks and
familiarise him or her with its use.
- Advise the user about possible hazards
(high water temperature)
- Hand over these instructions, to be kept
in a safe place.
1.9 Service note
When carrying out any work,
isolate the unit from the
mains
and shut off the water connection.
- Clean the filter
Disconnect the union nut, remove washer ,
filter and clean.
Re-assemble in reverse order.
1.10. Warning
When selecting the temperature
at the draw off fitting, high water
temperatures may be reached. Children,
especially, should be kept from the fitting
due to the risk of scalding.