27
UK
•Press
M
again to confirm.
>A confirmation tone is played.
•Press O to return to standby mode.
12.8.5 Delete All Entries from the Redial List
•From the home screen, press
-
.
•Press
M
.
•Press . to “DELETE ALL” and then press
M
to select.
>“CONFIRM?” is displayed.
•Press
M
again to confirm.
>A confirmation tone played.
13 TECHNICAL DETAILS
STANDARD DECT
FREQUENCY RANGE 1.88 TO 1.9 GHZ (BANDWIDTH = 20 MHZ)
CHANNEL
BANDWIDTH
1.728 MHZ
OPERATING RANGE UP TO 300M OUTDOORS; UP TO 50M INDOORS
OPERATING TIME STANDBY: 100 HOURS, TALKING: 10 HOURS
BATTERY CHARGE TIME:15 HOURS
TEMPERATURE RANGE OPERATING 0
0
C TO 40
0
C, STORAGE -20
0
C TO 60
0
C
ELECTRICAL POWER BASE UNIT:
VT04EUK06045 / VT04EEU06045
INPUT 100-240VAC 50/60HZ 150MA, OUTPUT 6VDC
450MA
TENPAO:S003IB0600045/S003IV0600045
INPUT 100-240VAC 50/60HZ 150MA, OUTPUT 6VDC
450MA
RJ-AS060450B001 / RJ-AS060450E002
INPUT 100-240VAC 50/60HZ 150MA, OUTPUT 6VDC
450MA
BATTERY INFORMATION
TYPE NI-MH (RECHARGEABLE BATTERY) 400MAH,
2 X 1.2V AAA