CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
CAUTION!
Do not connect the cable without cable
end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove a part of the insulation of black
and brown cable ends.
3. Apply a new end wire sleeve on each
wire's end (special tool required).
Two-phase connection: 400 V2N~ One-phase connection: 220 - 240 V~
5x1,5 mm² or 4x2,5 mm² 5x1,5 mm² or 3x4 mm²
Green - yellow Green - yellow
N Blue and blue Blue and blue N
L1 Black Black and brown L
L2 Brown
ENGLISH 9