In case of exhaust installation a window
switch might be required (consult an
authorised technician). You need to buy it
separately as it is not supplied with the
hob. The window switch has to be
installed by an authorised technician.
Refer to the installation booklet.
min.
50mm
min.
500mm
If the appliance is installed above a drawer,
the hob ventilation can warm up the items
stored in the drawer during the cooking
process.
Find the video tutorial "How to install your
AEG Extractor Hob 70 cm" by typing out the
full name indicated in the graphic below.
www.youtube.com/electrolux
www.youtube.com/aeg
How to install your AEG
Extractor Hob 70 cm
Filter housing assembly
Before the first use make sure to insert the
long life carbon filters inside the housing with
the handles facing inwards. Refer to
"Cleaning the hood filters". Once the filter
housing is assembled, put it inside the hood
system and place the grid on the hood.
3.4 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable, use
the cable type which withstands a
temperature of 125 °C or higher.
The single wire must have a diameter of
minimum 1,5 mm².
Speak to your local Service Centre. The
connection cable may only be replaced by
a qualified electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
8 ENGLISH