7.3.3 MEASUREMENTS
Select this menu item to find the following measurements in this order:
Power Usage Efficiency [%]
Output
(active and apparent power)
[W] & [VA]
Output
(current and power factor)
[A]
Output
(voltage and frequency)
[V] & [Hz]
Input
(voltage and frequency)
[V] & [Hz]
Battery
(voltage and charge state)
[V] & [%]
DC bus
(intermediate circuit voltage)
[V]
External battery modules
Total kWh consumption [kWh]
If you want to see any particular measurement on the screen
permanently, you can “freeze” the screen in the Measurements menu.
To do so, press “” and “” for approx. 3 seconds at the same time
until a small key appears in the upper right-hand corner of the display.
Press the two buttons again at the same time for approx. 3 seconds to
cancel this setting control.
7.3.4 CONTROL
During normal mode, you can active this menu item to access
the following sub-menu items: “Go to bypass”, “Battery test” and
“Reset error state”.
Depending on the operating mode, only those sub-menu items that are
available will appear.