EasyManua.ls Logo

AEG Protect C.2000 User Manual

AEG Protect C.2000
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OPERATING INSTRUCTIONS
EN
Protect C.1000
Protect C.2000
Protect C.3000
Protect C
Question and Answer IconNeed help?

Do you have a question about the AEG Protect C.2000 and is the answer not in the manual?

AEG Protect C.2000 Specifications

General IconGeneral
Noise level45 dB
Output power1400 W
Power factor0.96
Response time300 ms
Input frequency50/60 Hz
Maximum current10 A
Audible alarm(s)Yes
Output power capacity2 kVA
Output voltage Total Harmonic Distortion (THD)4 %
InterfaceRS-232
Networking featuresFast Ethernet
Output voltage note220 - 240V +/-2%
Compatible operating systemsWindows Mac OS Linux Unix Sun
Battery technologySealed Lead Acid (VRLA)
Battery recharge time5 h
Typical backup time at full load10 min
Typical backup time at half load30 min
Form factorTower
CertificationCE, EN 50091-2, EN 61000-3-2, EN 61000-6-3
Serial ports quantity1
Number of output IEC jumpers6
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Depth460 mm
Width192 mm
Height340 mm
Weight34004 g

Summary

Safety Instructions

3.1 General Safety Instructions

Provides general safety rules and explains pictograms used in the manual.

3.2 Safety Instructions for PROTECT C

Details specific safety warnings and precautions for the PROTECT C UPS.

Handling and Electrical Safety

Precautions for unit handling, installation, and electric shock hazards.

Battery Safety Precautions

Covers safety for authorized persons, battery handling, and disposal.

Set-Up and Operation

Overview of Connections and Elements

Commissioning the UPS

6.1 Mechanical Set-Up

Instructions for physically placing and setting up the UPS and battery units.

6.2 External Battery Extension

Guides on connecting external battery packs for extended backup time.

6.4 Consumer Connection

Instructions on connecting loads (consumers) to the UPS outlets.

Load Connection Safety

Safety warnings for load connection and emergency shutdown function.

Operation and Usage

7.1 Initial Installation and Switching

Steps for turning the UPS on, its initial synchronization, and switching off.

7.3.1 UPS Status Display

Explains how to access and interpret the UPS status display.

UPS Status Symbols and Examples

Explains display symbols and provides examples of different UPS status interpretations.

Interfaces and Communication

Trouble Shooting

9.1 Malfunctions Guide

Guides on interpreting error messages and troubleshooting UPS malfunctions.

Alarm and Error Message Guide

Lists specific alarms, their causes, and recommended actions.

Battery and Power Related Alarms

Details alarms for battery status, utility power, and wiring faults.

Operational and Internal Fault Alarms

Covers alarms for overload, voltage, frequency, short circuit, and temperature.

Maintenance Procedures

10.3 Battery Replacement

Provides safety precautions and procedures for replacing batteries.

Storage, Dismantling, and Disposal

Related product manuals