Water/Methanol Injection V210
© 2020 AEM Performance Electronics
Pump/Tank Flush
After all wires are hooked up, add water to the tank and, with the hose pointed into a container, press and hold
the TEST push button on the controller module. The TEST button can be used to test the system. The pump
speed will gradually increase from zero to full speed within 3 seconds and then remain full for another 3
seconds before stopping. Repeat the TEST button procedure until you are sure the system is free of any debris
that may have been in the lines or tank. Drain the water out of the tank and refer to the next section on installing
the nozzle.
Nozzle Selection
This injection kit includes three differently sized atomizing pintles that cover a very large range of horsepower
levels. Use the following chart to select the appropriate pintle for your power level. The kit comes with the 500cc
pintle already preassembled.