4 Yelllow
5 Pink
6 Cyan
7 Purple
8 Orange
15. Wakeup report LED.
This setting changes the color of the LED when your TriSensor sends a wakeup report.
Parameter
#
Size Value Description
15 1 0 Disable [Default]
1 Red
2 Green
3 Blue
4 Yelllow
5 Pink
6 Cyan
7 Purple
8 Orange
Temperature controls.
20. Temperature Scale Setting.
You can control what scale is reported from your temperature sensor.
Parameter
#
Region Size Value Default
20 EU/AU 1 0 - 1 0
US 1 0 - 1 1
Value and Description;
0 = Celcius
1 = Fahrenheit
21. Temperature Threshold reporting.
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scales
with Parameter 64 change to C or F. Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on
Parameter 64) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F).
Parameter
#
Size
Value
Description
21
2
0
Disable Threshold Report for Temperature Sensor
1 -
250
Sets threshold for inducing automatic report using
a scale of
0.1 * value = temperature threshold
23. Temperature automatic report based on time.
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is
longer.