Do you have a question about the AERMEC VED 541 and is the answer not in the manual?
Important warnings about power supply, water circuit, and proper voltage usage.
Details on filter cleaning, normal operations, and extraordinary cleaning methods.
Guidance on handling malfunctions, electrical safety, and child supervision.
Steps for removing, cleaning, and replacing the air filter.
Covers installation options, factory settings, and speed adjustment for ducted units.
Specifies maximum and minimum operational limits for water and ambient temperatures.
Details on relative humidity limits and power supply specifications for the units.
Recommendations on water temperature for efficient operation and preventing issues.
Technical data for heating output and pressure drop for 2-pipe systems.
Technical data for cooling capacity and water flow rates for 2-pipe systems.
Technical data for heating output and pressure drop for 4-pipe systems.
Technical data for cooling capacity and water flow rates for 4-pipe systems.
Table showing cooling capacity (Pc/Ps) for VED430 at various water/air temperatures.
Factors to adjust cooling capacity based on fan speed for VED430.
Continuation of the VED430 cooling capacity table.
Continuation of correction factors for VED430.
Table showing cooling capacity for VED440/441 at various temperatures.
Factors to adjust cooling capacity based on fan speed for VED440/441.
Continuation of the VED440/441 cooling capacity table.
Continuation of correction factors for VED440/441.
Table showing cooling capacity for VED530 at various temperatures.
Factors to adjust cooling capacity based on fan speed for VED530.
Continuation of the VED530 cooling capacity table.
Continuation of correction factors for VED530.
Table showing cooling capacity for VED540/541 at various temperatures.
Factors to adjust cooling capacity based on fan speed for VED540/541.
Continuation of the VED540/541 cooling capacity table.
Continuation of correction factors for VED540/541.
Table showing cooling capacity for VED630 at various temperatures.
Factors to adjust cooling capacity based on fan speed for VED630.
Continuation of the VED630 cooling capacity table.
Continuation of correction factors for VED630.
Table showing cooling capacity for VED640/641 at various temperatures.
Factors to adjust cooling capacity based on fan speed for VED640/641.
Continuation of the VED640/641 cooling capacity table.
Continuation of correction factors for VED640/641.
Table showing cooling capacity for VED730 at various temperatures.
Continuation of the VED730 cooling capacity table.
Table showing cooling capacity for VED740/741 at various temperatures.
Continuation of the VED740/741 cooling capacity table.
Covers essential safety warnings before and during installation work.
Step-by-step instructions for mounting the fan coil unit correctly.
Procedures for checking the installation, condensate system, and performing a functional test.
Essential warnings and requirements for safe electrical connections.