EasyManua.ls Logo

AERMEC WMT21 - Temperature Unit Settings

AERMEC WMT21
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISHAPPENDIX A DEUTSCH ITALIANOFRANÇAISESPAÑOL
131
FAHRENHEIT DEGREES TEMPERATURE SETTING
In order to set the measurement unit from Celsius degrees to Fahrenheit
degrees and vice versa, enter the conguration mode by holding down the
keys and until the display shows Con”, then hold down the
two keys and for a few seconds, until the display returns to
the usual screen.
Switching from Celsius to Fahrenheit or vice versa also forces a reset of
the installer conguration to default values.
0. 0
P12
Room temperature
offset (°F)
12. 0..12. 0
50
P13
Heating set-point
lower limit (°F)
41 ..95 
86
P14
Heating set-point
upper limit (°F)
41 ..9 5    
50
P15
Cooling set-point
lower limit (°F)
41 ..95 
86
P16
Cooling set-point
upper limit (°F)
41 ..95 
32
P17
Anti-freeze threshold
temperature (°F)
32 .. 6 0
0
P18
Economy
reduction (°F)
0 ..18
0. 4
P19
Room temperature
hysteresis (°F)
0. 4 ..1. 8
5. 0
P20
Neutral zone
width (°F)
0. 0 ..20. 0
0
P21
Fan delay at
turn-on (seconds)
0 ..600
0
P22
Fan delay at
turn-off (seconds)
0 ..600
104
P23
Heating delivery
temperature threshold (°F)
32 ..210
59
P24
Cooling delivery
temperature threshold (°F)
32 ..210
0
P25
Dirty lter warning
time (x 100 hours)
0 .. 5 0
-

Table of Contents