Jet Pumps
INSTALLATION AND OPERATION MANUAL
Models HNAS Series Single Stage
Horsepower Range: 1/2 - 1 H.P.
60 Cycle
Single Phase Installations
Owners Record
Pump Model:
Pump Serial No.:
Pump Date Code:
Motor H.P. Voltage Phase
Date of Installation:
Owner:
Installer:
Installer Phone Number:
AERMOTOR
293 Wright St., Delavan, WI 53115
Printed in U.S.A. ©2003 AER416 (Rev. 7/9/03)

Questions and Answers

  • B
    Benjamin EspinozaAug 8, 2025
    What to do if aermotor HNAS Water Pump cycles too frequently?
    • J
      jeffreymcleanAug 8, 2025
      To resolve frequent cycling or failure to shut off in your Aermotor Water Pump, first, check for open faucets. If your system uses a standard tank, ensure it's not waterlogged by draining it to the air volume control level. Inspect the AVC for defects and check all connections for leaks.
  • P
    Patricia DanielsAug 12, 2025
    What to do if aermotor HNAS motor runs but no water comes out?
    • R
      Robert OconnellAug 12, 2025
      If your Aermotor Water Pump motor runs but no water is delivered, start by checking the prime. Make sure the pump, suction piping, and well piping are full of water. In cold weather, ensure pipes and the pump aren't frozen. If frozen, thaw carefully, watching for splits in pipes and fittings. Consider heating the pump pit or pump house and burying piping below the frost line.
  • L
    Laura JacobsAug 16, 2025
    Why is my aermotor HNAS not delivering water to full capacity?
    • U
      uhaleyAug 16, 2025
      If your Aermotor Water Pump isn't delivering water to its full capacity, the well water level might be lower than estimated, requiring a different nozzle/venturi combination. Also, check for corrosion or lime buildup in steel piping, which can restrict capacity. Ensure the piping isn't too small for your installation.
  • J
    jillianhoganAug 21, 2025
    Why does my Aermotor Water Pump motor run hot and overload trips?
    • C
      Christopher ThorntonAug 21, 2025
      If the Aermotor Water Pump motor runs hot and the overload trips, refer to the electrical instructions to confirm correct wiring. Verify with your power company that the voltage at the pump is within +10% of the motor's rated voltage. Disconnect power and ensure the wires connecting the motor to the power supply are properly sized.
  • B
    Bruce NunezAug 25, 2025
    Why is there air coming out of the faucets with my Aermotor Water Pump?
    • S
      Sarah KelleyAug 25, 2025
      To address air spurts from the faucets with your Aermotor Water Pump, the pump may still be priming. Once priming is complete, all air should be ejected from the system.
  • A
    aliciafernandezAug 29, 2025
    How to fix aermotor HNAS leaks around the clamp?
    • C
      Crystal HaydenAug 29, 2025
      To fix a leak around the clamp of your Aermotor Water Pump, tighten the clamp nut by 1-2 turns. Avoid overtightening.
  • J
    Jordan EstesSep 2, 2025
    What to do if aermotor HNAS Water Pump motor will not run?
    • E
      Erin KellySep 2, 2025
      To troubleshoot an Aermotor Water Pump motor that won't run, check that the disconnect switch is ON and that the circuit breaker hasn't tripped or the fuse hasn't blown. Disconnect the power and ensure that wires connecting the motor to the power supply and pressure switch are tight and correctly connected.