6.4 Parameter checking and adjustment
Unit running status query table
1. On main interface, press to check unit running status, use and buttons to
check each parameter. Please refer to a list of relevant unit running parameters below.
2. Press to go back to main interface screen.
Code
Parameter Name
Description
Typical Range
A1
Coil temp
Evaporator coil temperature.
(-10)-15
(Heat)
35-48
(Cool)
A2
Compressor suction gas
temp
Refrigerant gas temperature at the
inlet of the
compressor.
(-10)-15
(Heat)
10-25
℃(
Cool
A3
Compressor exhaust
gas
temp
Refrigerant gas temperature at the
outlet of the
compressor.
40-80
(Heat)
60-95
℃(
Cool
A4
Ambient air temp
Surrounding ambient air temperature.
(-10)-45
A5
Outlet water temp
Water temperature at the outlet of the heat pump
(return to pool).
5-40
A6
Compressor current
Displays the compressor current (3-Phase
units
only).
5-10A
A7
Opening of the EEV
Opening angle of the EEV (Electronic Expan
sion Valve).
10-60
E1-E6
Error code display
Displays up to 6 error codes.
None
-
-
Automated Environmental Systems Ltd., Unit 1, 1 Wimbledon Avenue, Brandon, Suffolk IP27 0NZ