6.4 Parameter checking and adjustment
Unit running status query table
1. On main interface, press to check unit running status, use and buttons to
check each parameter. Please refer to a list of relevant unit running parameters below.
2. Press to go back to main interface screen.
Evaporator coil temperature.
(-10)-15
℃
(Heat)
35-48
℃
(Cool)
Compressor suction gas
temp
Refrigerant gas temperature at the
inlet of the
compressor.
(-10)-15
℃
(Heat)
10-25
℃(
Cool
)
Compressor exhaust
gas
temp
Refrigerant gas temperature at the
outlet of the
compressor.
40-80
℃
(Heat)
60-95
℃(
Cool
)
Surrounding ambient air temperature.
Water temperature at the outlet of the heat pump
(return to pool).
Displays the compressor current (3-Phase
units
only).
Opening angle of the EEV (Electronic Expan
sion Valve).
Displays up to 6 error codes.
-
-