25
Maintenance
EN
DTA 10
8 Maintenance
8.1 Maintenance intervals
8.2 Maintenance activities
1. Proceed as described in chapter "Inserting/connecting the battery".
- Stored settings are not lost when the battery is replaced.
9 Troubleshooting
Any malfunctions that cannot be removed by means of the measures
described in this chapter may only be repaired by the manufacturer.
When Activity
If required Replace battery
Problem Possible reason Repair
Display does not show
anything
9 V monobloc battery is
empty
Insert a new 9 V monob-
loc battery
Incorrect level indication Incorrect tank data
entered
Incorrect tank shape
entered
Measuring line does not
reach down to the tank
bottom
Leak in measuring line
Correct the tank data
(see
chapter "Commissionin
g the product")
Check the measuring
line in the tank
Other malfunctions - Contact the AFRISO
service hotline