Problem Possible Cause Remedy
Unit not cold enough.
Adjust temperatures (See
"Changing Current Set-
tings" on page 6).
Control set too warm.
Content temperature not stabilized.
Excessive usage or prolonged door
openings.
Airow to front grille blocked.
Door gasket not sealing properly.
Adjust temperature colder. Allow 24
hours for temperature to stabilize.
Allow temperature to stabilize for at least
24 hours, with minimal door openings.
Airow must not be obstructed to front
grille. See "clearances" on page 4.
Check door alignment and/or adjust or
replace door gasket.
Unit too cold.
Adjust temperatures (See
"Changing Current Set-
tings" on page 6).
Control set too cold.
Door gasket not sealing properly.
Adjust temperature warmer. (See page
6, "set the desired temperature"). Allow
24 hours for temperature to stabilize.
Check door alignment and/or adjust or
replace door gasket.
No interior light inside
cabinet.
Bulb burned out. See "Care and Cleaning" page 16 or
contact a qualied Aga Marvel service
representative.
Light will not go out when
door is closed.
Door not activating light switch.
Display light function has been activated.
Verify cabinet is level, refer to page 4 for
leveling instructions.
Verify the door is aligned properly, refer
to page 11 for instructions.
Turn off display lighting.
Noise or Vibration. Unit not level Level unit, see "Leveling Legs" on page
4.
Unit will not run. Unit turned off
Power cord not plugged in.
No power at outlet.
Turn unit on. See "Start your Appliance"
on page 6.
Plug in power cord.
Check house circuit.
Before You Call for Service
If the unit appears to be malfunctioning, read through this
manual rst. If the problem persists, check the trouble-
shooting guide below. Locate the problem in the guide and
refer to the cause and its remedy before calling for service.
The problem may be something very simple that can be
solved without a service call. However, it may be required
to contact a qualied service technician.
Electrocution Hazard
Never attempt to repair or perform maintenance on the
unit until the main electrical power has been disconnected.
Turning the unit control "OFF" does not remove electrical
power from the units wiring.
17