6 AGA Ellesmere Standard Gas Stove
2. User instructions.
2.1 Emergency Gas Isolation
When installing this stove the Gas Safe Installer must fit a gas isolation valve at the rear of the stove
with a pressure test point incorporated into the On/OFF Tap - Please make the customer aware of
where this valve is fitted
In the event of a gas leak or if gas is smelt, the appliance must be isolated. This is done by turning OFF
the gas at the Isolation Tap. This Isolation Tap should be fitted to the rear or side of the appliance.
2.2 First Time of Operation
Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping
have been removed, and that the glass has been cleaned, including all fingerprints from the glass.
Ensure that the room is adequately ventilated the first time that the appliance is ignited; we would
recommend opening windows if possible.
Curing the Paint
Run the appliance at a 25% setting for a 1 hour
Then at a 50% Setting for 1 hour
Then Finally on Full Power 100% for 1 hour
This will then allow the paint the opportunity to fully cure. During this period it is possible for
some fumes and vapours to be given off.
We would recommend keeping children and pets out of the area at this time.