12
Rotate the laser 180°, allow it to self level and mark the opposite side
of the first axis (Position 2).
• Align the Y-axis by rotating the laser 90° so that this axis is now square
to the wall. Allow the laser to self- level completely, and then mark the
position of the beam (Position 3).
Rotate the laser 180°, allow it to self level and mark the opposite side
of the Y-axis (Position 4).
The laser is within its accuracy specification if the four marks are
within ± 3 mm 1/8") from the center.
Checking vertical accuracy
To check the vertical accuracy of your laser, place the unit in the laydown
position on a flat, level surface approximately 15-30 meters (50-100 ft.)
from a wall.
Hang a plumb line on the wall.
Move the laser until the vertical, rotating beam is aligned to the plumb line.
If the rotating beam is not plumb, adjustment is necessary.
Adjusting level accuracy -
The X-axis
After checking the accuracy of your laser, perform the following steps to
adjust the accuracy of the X-axis.
Turn off the laser.
Press and hold the H.I. key {B-2}, then press the ON/OFF key {B-1}.
• After the three LEDs blink three times simultaneously, release the H.I. key.
- The X-axis LED will flash rapidly (red) while leveling
- The X-axis LED will flash slowly (red) when ready for adjustment.
- The head will not be rotating.
- Press the Scan/Rotation key {C-3} to start rotation mode.