EasyManua.ls Logo

Agilent Technologies 4339B - Page 113

Agilent Technologies 4339B
287 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4339B
Rear
P
anel
T
able 3-4.
Contact Assignment
for
Comparator
Function
Pin
No
.
Signal
Name
1
Description
1
2
EXT DCV1
EXT
DCV1
External DC
Voltage
1:
DC
voltage supply
pins
for
DC
isolated
open
collector
outputs
(/HI,
/IN/,
/LO/,
/NO
CONT
A
CT).
Maximum voltage
is +24
V,
minimum +5
17 /HV
OFF
V
oltage
Source
OFF:
When
this
line
is
asserted,
output
of
the
voltage
source is
disabled.
18 /KEY
LOCK
Key
Lock:
When
this
line
is
asserted,
all
of
the 4339B
's front
panel key
functions are
disabled.
19 /EXT
TRIG
External
Trigger:
4339B
is
triggered
on
the
rising
edge
of
a
pulse applied
to this
pin when
the trigger
mode
is
set
to
the
External.
2
20
21
EXT
DCV2
EXT
DCV2
External
DC
voltage
2:
DC
voltage
supply
pins
for
DC
Isolated inputs
(/EXT TRIG,
/KEY LOCK,
/HV
OFF)
and
DC
Isolated outputs
(/INDEX, /EOM,
/NOT
READY
,
/ALARM).
Maximum
voltage
is
+15
V
,
minimum
+5
V
24
25
+5
V
+5
V
Internal
voltage
supply
(max.
output 0.1
A):
Exceeding
0.1
A
will
cause
the
internal
voltage
output
and
the
output
signals
to
got
to
zero.
26
27
COM1
COM1
Common for
EXT
DCV1
28 /HI This signal
is asserted,
when
the
comparison
result
is
High.
3
29 /IN This
signal
is
asserted,
when
the
comparison
result
is
In.
3
30 /LO This
signal
is
asserted,
when
the
comparison
result
is
Low
.
3
37 /NO
CONT
A
CT
This
signal
is
asserted,
when
the
contact
check failed.
3
41 /NOT
READY
Not
ready:
This
signal
is
asserted
when the
current
owing
through
the
DUT
exceeds
the
current
limit.
42 /ALARM Alarm:
This
signal
is
asserted
when
a
power
failure
occurs
or the
error (
E11, E12,
E13,
E14,
E15, E20
or
E-313
)
occurs
.
43 /INDEX Index:
This
signal
is
asserted
when
an
analog
measurement
is
complete
and
the
4339B
is
ready
for
the
next
DUT to
be connected
to the
UNKNOWN terminals
.
The
measurement
data,
however
,
is
not
valid
until /EOM
is asserted.
44 /EOM End
of
Measurement:
This signal is asserted when the measurement data and comparison results are valid.
45
46
COM2
COM2
Common for EXT
DCV2
49
50
GND
GND
Ground tied to chassis
.
1
The / (slash) means that the signal is asserted when low
.
2
If an error
occurs and the 4339B stops operation, the 4339B will not trigger a measurement after receiving the /EXT
TRIG signal.
3
If an error occurs and the 4339B stops operation, these lines maintain the condition just before the error occurred.
Function Reference 3-23

Other manuals for Agilent Technologies 4339B

Related product manuals