Language Dictionary - 8
101
MEASure:CURRent:HIGH?
FETCh:CURRent:HIGH?
These queries return the High level current of a current pulse waveform. The instrument first measures
the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse
waveform using 16 bins between the maximum and minimum data points. The bin containing the most
data points above the 50% point is the high bin. The average of all the data points in the high bin is
returned as the High level. If no high bin contains more than 1.25% of the total number of acquired
points, then the maximum value is returned by these queries.
Query Syntax
MEASure[:SCALar]:CURRent:HIGH?
FETCh[:SCALar]:CURRent:HIGH?
Parameters
None
Examples
MEAS:CURR:HIGH? FETC:CURR:HIGH?
Returned Parameters
<NR3>
Related Commands
MEAS:CURR:LOW? CALC:REF:HIGH
MEASure:CURRent:LOW?
FETCh:CURRent:LOW?
These queries return the Low level current of a current pulse waveform. The instrument first measures
the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse
waveform using 16 bins between the maximum and minimum data points. The bin containing the most
data points below the 50% point is the low bin. The average of all the data points in the low bin is
returned as the Low level. If no low bin contains more than 1.25% of the total number of acquired points,
then the minimum value is returned by these queries.
Query Syntax
MEASure[:SCALar]:CURRent:LOW?
FETCh[:SCALar]:CURRent:LOW?
Parameters
None
Examples
MEAS:CURR:LOW? FETC:CURR:LOW?
Returned Parameters
<NR3>
Related Commands
MEAS:CURR:HIGH? CALC:REF:LOW
MEASure:CURRent:MAXimum?
FETCh:CURRent: MAXimum?
These queries return the maximum output current.
Query Syntax
MEASure[:SCALar]:CURRent:MAXimum?
FETCh[:SCALar]:CURRent:MAXimum?
Parameters
None
Examples
MEAS:CURR:MAX? FETC:CURR:MAX?
Returned Parameters
<NR3>
Related Commands
MEAS:CURR:MIN?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 66319D and is the answer not in the manual?

Agilent Technologies 66319D Specifications

General IconGeneral
BrandAgilent Technologies
Model66319D
CategoryPower Supply
LanguageEnglish

Related product manuals