118
STATus:OPERation:ENABle
This command and its query set and read the value of the Operational Enable register. This register is a
mask for enabling specific bits from the Operation Event register to set the operation summary bit
(OPER) of the Status Byte register. This bit (bit 7) is the logical OR of all the Operatonal Event register
bits that are enabled by the Status Operation Enable register.
Command Syntax
STATus:OPERation:ENABle<NRf>
Parameters
0 to 32767
Preset Value
0
Examples
STAT:OPER:ENAB 1312
Query Syntax
STATus:OPERation:ENABle?
Returned Parameters
<NR1> (register value)
Related Commands
STAT:OPER:EVEN
STATus:OPERation:NTR
STATus:OPERation:PTR
These commands set or read the value of the Operation NTR (Negative-Transition) and PTR (Positive-
Transition) registers. These registers serve as polarity filters between the Operation Enable and
Operation Event registers to cause the following actions:
$ When a bit in the Operation NTR register is set to 1, then a 1-to-0 transition of the corresponding bit
in the Operation Condition register causes that bit in the Operation Event register to be set.
$ When a bit of the Operation PTR register is set to 1, then a 0-to-1 transition of the corresponding bit
in the Operation Condition register causes that bit in the Operation Event register to be set.
$ If the same bits in both NTR and PTR registers are set to 1, then any transition of that bit at the
Operation Condition register sets the corresponding bit in the Operation Event register.
$ If the same bits in both NTR and PTR registers are set to 0, then no transition of that bit at the
Operation Condition register can set the corresponding bit in the Operation Event register.
Command Syntax
STATus:OPERtion:NTRansition<NRf>
STATus:OPERtion:PTRansition<NRf>
Parameters
0 to 32767
Preset Value
NTR register = 0; PTR register = 32767
Examples
STAT:OPER:NTR 32 STAT:OPER:PTR 1312
Query Syntax
STAT:OPER:NTR? STAT:OPER:PTR?
Returned Parameters
<NR1> (register value)
Related Commands
STAT:OPER:ENAB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 66319D and is the answer not in the manual?

Agilent Technologies 66319D Specifications

General IconGeneral
BrandAgilent Technologies
Model66319D
CategoryPower Supply
LanguageEnglish

Related product manuals