92
Table 8-1. Subsystem Commands Syntax (continued)
:PROTection
[:LEVel] <n>
Sets the programmable output voltage limit
:STATe <bool>
Enables/disables automatic overvoltage protection tracking
VOLTage2
[:LEVel]
[:IMMediate][:AMPLitude] <n>
Sets the output2 voltage level
:TRIGgered [:AMPLitude] <n>
Sets the triggered output2 voltage level
STATus
:PRESet
Presets all enable and transition registers to power-on
:OPERation
[:EVENt]?
Returns the value of the event register
:CONDition?
Returns the value of the condition register
:ENABle <n>
Enables specific bits in the Event register
:NTRansition<n>
Sets the Negative transition filter
:PTRansition<n>
Sets the Positive transition filter
:QUEStionable
[:EVENt]?
Returns the value of the event register
:CONDition?
Returns the value of the condition register
:ENABle <n>
Enables specific bits in the Event register
:NTRansition<n>
Sets the Negative transition filter
:PTRansition<n>
Sets the Positive transition filter
SYSTem
:ERRor?
Returns the error number and error string
:LANGuage <language>
Sets the programming language (SCPI)
:VERSion?
Returns the SCPI version number
TRIGger
:SEQuence2 | :ACQuire
[:IMMediate]
Triggers the measurement immediately
:COUNt
:CURRent <n>
Sets the number of sweeps per current measurement
:DVM <n>
Sets the number of sweeps per DVM measurement
:VOLTage <n>
Sets the number of sweeps per voltage measurement
:HYSTeresis
:CURRent <n>
Qualifies the trigger when measuring current
:DVM <n>
Qualifies the trigger when making DVM measurements
:VOLTage <n>
Qualifies the trigger when measuring voltage
:LEVel
:CURRent <n>
Sets the trigger level for measuring current
:DVM <n>
Sets the trigger level when making DVM measurements
:VOLTage <n>
Sets the trigger level for measuring voltage
:SLOPe
:CURRent <slope>
Sets the triggered current slope (POS | NEG | EITH)
:DVM <slope>
Sets the triggered DVM measurement slope (POS | NEG | EITH)
:VOLTage <slope>
Sets the triggered voltage slope (POS | NEG | EITH)
:SOURce <source>
Sets the trigger source (BUS | INT | TRIG)
[:SEQuence1 | :TRANsient]
[:IMMediate]
Triggers the output immediately
:SOURce <source>
Sets the trigger source (BUS)
:SEQuence1
:DEFine TRANsient
Sets or queries the SEQ1 name
:SEQuence2
:DEFine ACQuire
Sets or queries the SEQ2 name

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 66319D and is the answer not in the manual?

Agilent Technologies 66319D Specifications

General IconGeneral
BrandAgilent Technologies
Model66319D
CategoryPower Supply
LanguageEnglish

Related product manuals