– 5 –
Door or sub station to master station intercom wiring, single or multi-master station
Intercom Operation: 
·
 To initiate call at sub station, push the station's Call button.
·
 To answer sub station call at LEF-3, push the appropriate Station Selector button.
·
 To talk to sub station, press and hold TALK and release to listen. 
Notes:
 
1
 
from a sub station can wire to any number
 
1
,
 
2
, or
 
3
 
but never
 
C
.
C
 is only used for internal communication between master stations. See below.
Master to Master intercom wiring, internal communication between master stations
Important: Never wire
 
C
 
to another master station's
 
C
 terminal.
Master to sub intercom only, no internal communication between master stations 
Intercom Operation: 
·
 To initiate call at sub station, push the station's Call button.  
·
 To answer sub station call at LEF-3, push the appropriate Station Selector button.    
·
 To talk to sub station, press and hold TALK and release to listen.    
 
PS12
 
PS-1225UL, PS-1225S, PS-1225, PS-1215DIN
Choose either method.
Operation notes:
When operating M1, push #2 Station 
Selector button to listen to "M2", press 
and hold "TALK" to talk.
When operating M2, push #1 Station 
Selector button to listen to "M1", press 
and hold "TALK" to talk.
When operating either master station 
utilizing the "same channel method," 
push #3 Station Selector button to listen 
to the other master station, press and 
hold "TALK" to talk.
LE-SS/A series stations use colored leads
1
 is red lead
-
 is blue lead
E
 is black lead
Notes:
1
 from a sub station can go to
1
, 
2
 or 
3
 but never 
C
.
Only master stations can answer 
calls and communicate with sub 
stations.
* LE-SS/A is North America only.
1 
E
-
3 
2 
1 
E
- 
C 
R 
Y 
+
-
+
door station 
LEF-3
*Keep  E  /  
-
  jumpers
only for 2-wire setup
PS12
*
*
1 
E
-
3 
2 
1 
E
- 
C 
R 
Y 
+
3 
2 
1 
E
- 
C 
R 
Y 
+
-
+
LE series sub / 
door station 
*Remove  E  /  
-
  jumpers in
all multimaster systems
Multi-master 
LEF-3 LEF-3
PS12
*
3 
2 
C 
1 
E
+
Y 
- 
R 
3 
C 
1 
2 
E
+
Y 
- 
R 
+
-
LEF-3
LEF-3
PS12
-
+
C 
2 
1 
3 
E
3 
2 
1 
C 
E
+
Y 
- 
R 
+
Y 
- 
R 
LEF-3
using channel 3 
PS12 
-
+
3 
2 
1 
E
- 
R 
Y 
+
C 
3 
2 
1 
E
- 
R 
Y 
+
C 
1 
E
-
1 
E
-
Red 
Black
Blue
LEF-3 LEF-3
*Remove all  E  /  
-
  jumpers
LEF-3  “Parallel Method”
LE series sub / door station
LE-A / LE-DA etc
LE series sub / door station
LE-A / LE-DA etc
LE-SS/ A  series 
door station*
PS12
Red 
Black
Blue
4 
WIRING DIAGRAMS - Important Wiring Rules