Two LEF-5, Three LE-D w/Camera Call-up and Door Release
2 LEF-5, 2 Doors, 3 Speakers with Release and External Signaling
: PS-1225UL, PS-1225S,
PS-1215DIN
PS12
: Transformer for Strike
PT
: PS-1225UL, PS-1225S,
PS-1215DIN
PS12
: Transformer for Strike
PT
Note: This system configuration has
no master-to master communication.
The horns and speaker are shown on
channels 1 ~ 3. The door stations are
shown on channels 4 and 5. When the
door station calls, the respective relay
will trigger the external bell. Each door
station will ring a separate bell in this
example.
PT PT PT PT PT
PT PT
Note:
NP-B has two red wires. Use the red wire that is
connected directly to the capacitor on the PC board.
Capacitors shown are 15-33 µfd, 25V Non-Polarized (NP-25V)
Note:
This system configuration
has the master stations assigned
to channels 1 and 2, and the door
stations as 3 ~ 5. The relays
provide a maintained contact for
camera call-up, and a momentary
contact for selective door release.
: Diode Value: 1N4001~1N4007
Yellow (2)
+
E
1
Yellow (2)
To Strike
&
To Bell & Power
for station #4
To Bell & Power
for station #5
Black (2)
RY-PA
E
1
Yellow (2)
To Strike
&
Black (2)
RY-PA
+
5
3
C
1
R
E
Y
+
4
LEF-5 #2
2
5
3
2
C
R
E
Y
+
4
LEF-5 #1
1
1
E
E
1
1
E
Yellow (2)
To
Strike
&
RY-PA
Yellow (2)
Maintained
Contact*
To
Strike
&
Maintained
Contact*
To
Strike
&
Maintained
Contact*
RY-PA
Yellow (2)
RY-PA
Yellow (2)
RY-PA
Yellow (2)
RY-PA
Yellow (2)
RY-PA
5
3
2
1
R
E
Y
+
LL
K4
K5
4
LEF-5
5
3
2
1
R
E
Y
+
LL
K4
K5
4
LEF-5
LT-1
AH-108
NP-25V
Blue (2)
Red (2)
Red (2)
Red (2)
Black
Red
White
Black
Red
White
Blue (2)
NP-B
LT-1
AH-108
Blue (2)
SP-20N
NP-25V
Yellow (2)
RY-AC/A
RY-AC/A
PS12
Remove the shorting link between
“E” and “
-
” terminals at all the LEF
master and door/sub stations.
Remove the shorting link between
“E” and “
-
” terminals at all the LEF
master and door/sub stations.
PS12
*Maintained contact while station is selected.
Connect to video switcher, multiplexer, etc.
LE-D or LE-DA
LE-D or LE-DA
LE-D or LE-DA
LE-D or LE-DA
LE-D or LE-DA
Black (2)
Black (2)
Black (2)
Black (2)
Black (2)
Black (2)
LL
K3
K4
K5
LL
K3
K4
K5

Other manuals for Aiphone LEF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aiphone LEF Series and is the answer not in the manual?

Aiphone LEF Series Specifications

General IconGeneral
MaterialABS Plastic
ColorWhite
Audio Frequency Response300Hz - 3.4kHz
Wiring2-wire
Door ReleaseYes

Related product manuals