Loading...
Brochure I0607B Rev. 04-03-19
209 Citation Drive, Units 5 & 6
Concord, ON, Canada, L4K 2Y8
Telephone (905) 264-1414
Fax (905) 264-1147
E-mail: info@airmaxtechnologies.com
Web Site: www.airmaxtechnologies.com
MaxAir 30(e), 50(e), 70(e), 100(e) Low
Velocity (LV) Fan Coil Systems
Combination Heating/Cooling Equipment
Design, Installation and Maintenance
Instructions
AirMax Technologies Mini Ducted
MaxAir(e) fan coil systems
Important: Read and save these instructions.
Install in accordance with CEC and NEC; All wiring shall conform to CEC, NEC, and
local building and electrical codes.
CERTIFIED
FAN COIL UNITS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Airmax MaxAir 30e LV and is the answer not in the manual?

Summary

EQUIPMENT SELECTION AND SIZING

Selecting the fan coil

Guides the designer in selecting the appropriate MaxAir™™ fan coil model based on heat load calculations.

INSTALLATION

air handler mounting

Provides instructions and precautions for mounting the air handler in various configurations.

domestic water piping

Details requirements for installing domestic water piping, including sediment faucets and isolation valves.

cooling coil & TX valve

Instructions for installing the accessory slab cooling coil and the TX valve for proper operation.

fan coil placement

Discusses factors influencing fan coil placement for optimal performance and accessibility.

condensation

Addresses condensate formation on cooling coils and cabinets, and secondary drain pan requirements.

DX refrigerant cooling

Highlights requirements for installing DX evaporator coils, including level installation and drain pan trapping.

freezestat and TX valve

Explains the installation and placement of the anti-ice control and TX valve sensing bulb.

evacuating and charging

Describes the process for evacuating and charging the refrigeration system to ensure proper operation.

ELECTRICAL (STANDARD UNITS)

ELECTRICAL (MAXe UNITS)

CONTROL SYSTEM INPUTS

Details the 0-10VDC command input and its specifications for controlling fan speed and volume.

Switched 24 VAC INPUTS

Explains the discrete 24VAC inputs for selecting operational modes like heating, cooling, and fan-only.

DIP-SWITCHES: FLOW VOLUME SELECT OPTIONS

Explains how dip-switches are used to select flow levels for various discrete input states.

ONE AND TWO STAGE HEATING SYSTEM SELECTOR

Details the selection of single or two-stage heating control via thermostat and dip-switches.

START-UP PROCEDURES

SERVICE AND MAINTENANCE

TROUBLESHOOTING

WIRING DIAGRAM (STANDARD UNITS)

WIRING DIAGRAM (MAXe UNITS)

SAMPLE PIPING SCHEMATICS

Airmax MaxAir 30e LV Specifications