5.4.2 Installation of the unit into the housing
Step 1. Remove the front panel and the air lter.
Hold the slot under the front panel, then uplift it outwards, and remove the front
panel (See Fig.1). Pinch the handle under the air lter and make the air lter arched,
remove it from the slot from underside to upside (See Fig.2).
Step 2. Remove the frame.
Remove the two xing screws from the frame (See Fig.3).
Grasp the left corner of the frame's underside, then loosen the frame (See Fig.4).
Step 3. Installation.
For <9000Btu/h models, remove the two xing screws on the chassis xing
brackets, then remove the chassis xing bracket;
For 9000Btu/h modes, remove the front two screws only.
Then remove the four screws located on both sides and back sides of the cabinet.
(See Fig.5).
Grasp the handle on the chassis and carefully slide the air conditioner out of the
cabinet (See Fig.6).
Remove shipping pad from around compressor before operation and make sure the
discharge points to the drain pan are aligned before the chassis is pushed into the
cabinet (See Fig.7).
Push the unit chassis into the cabinet (See Fig.8).
Install the two chassis xing brackets using the two xing screws (See Fig.5).