1
30" AND 36" ISLAND-MOUNT RANGE HOOD
Universal Installation Instructions and Use & Care Guide
For questions about features, operation/performance parts, accessories or service, call:
1-626-453-0550
or visit our website at...
www.akdytrading.net
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
Model: GVA-I
668I GVC-I
668IS2 GVA-IS2
610I 627I
688I

Questions and Answers

  • G
    gary92Aug 7, 2025
    Why is my AKDY Ventilation Hood fan not working?
    • M
      Madeline JonesAug 7, 2025
      There are a couple of reasons why the fan in your AKDY Ventilation Hood might not be working. It could be due to a malfunctioning electronic control caused by over voltage, in which case you should replace the control and user interface. Alternatively, the motor connector may have become loose during cleaning, causing a false contact in the main harness. To fix this, remove power supply from the hood, open the control box, and check that the connector from the motor is securely connected to the connector on the plastic, ensuring the locking system is engaged. If not, press the main connectors attached to the white plastic and push the motor/lamp connectors inward until the locking system is properly attached. Then, reconnect the hood to the power supply and test it.
  • M
    Marissa FosterNov 17, 2025
    What to do if AKDY Ventilation Hood lamp does not turn on?
    • M
      Madison EnglishNov 17, 2025
      If the lamp on your AKDY Ventilation Hood isn't turning on, it could be due to several reasons. First, the electronic control might not be working due to over voltage; in this case, replace the control and user interface. Second, the lamp itself might be non-functional. Remove the lamp and check if the filament is burned or not correctly placed; replace the lamp if necessary. Finally, the motor connector may have become loose during cleaning, causing a false contact in the main harness. To resolve this, remove power supply from the hood, open the control box, and ensure the connector from the motor is securely connected to the connector on the plastic, making sure the locking system is well locked. If the connectors are not well connected: - Hold and press main connectors attached in the ...
  • L
    Lisa ShawNov 26, 2025
    How to fix noisy blower on AKDY 688I Ventilation Hood?
    • S
      Sarah JimenezNov 26, 2025
      A noisy blower in your AKDY Ventilation Hood can be caused by dirty filters or a false contact in the connectors. First, check if the grease and/or charcoal filters are clean. If they are dirty, replace the charcoal filter or wash the grease filter. If the filters aren't the issue, the problem might be a loose connection. To check this, remove power supply from the hood, open the control box, and verify that the connector coming from the motor is securely connected to the connector mounted in the plastic, ensuring the locking system is well locked. If the connectors are not well connected: - Hold and press main connectors attached in the white plastic. - Push inwards the motor/lamp connectors until the locking system on connectors is well attached. Reconnect the hood to the power supply...

Summary

Range Hood Safety

Safety Alert Symbols

Explains DANGER and WARNING symbols to indicate potential hazards.

Important Safety Instructions

General Safety Precautions

Covers fire, electric shock, injury prevention, proper usage, and ventilation.

Installation Requirements

Tools and Parts

Lists necessary tools and parts supplied for installation.

Location Requirements

Specifies ideal placement and clearance dimensions for the range hood.

Installation Dimensions

Details height and clearance measurements for installation.

Venting Requirements

Details vent system requirements, methods, and considerations.

Electrical Requirements

Power Supply and Wiring

Outlines electrical circuit, wiring, and code compliance.

Installation Instructions

Prepare Location

Steps for preparing the installation site, including measurements and cutouts.

Installation Steps

Covers preparation, mounting, and connecting the range hood components.

Mount Range Hood

Instructions for attaching the main hood body and securing it.

Finalize Installation

Specific steps for completing the installation for non-vented models.

Range Hood Use

Controls and Operation

Explains the function of various control buttons and settings.

Range Hood Care

Cleaning

Guidelines for cleaning exterior surfaces and metal grease filters.

Filter and Component Maintenance

Information on replacing carbon filters and LED lights.

Trouble Shooting

Common Issues and Solutions

Lists potential problems and recommended actions for resolution.

Limited Warranty

Warranty Exclusions

Details items and conditions not covered by the limited warranty.

Legal Disclaimers

States limitations on implied warranties and consequential damages.

AKDY 688I Specifications

General IconGeneral
BrandAKDY
Model688I
MaterialStainless Steel
Number of speeds3
Filter TypeBaffle Filter
Noise Level65 dB
Vent TypeDucted
LightingLED
Control TypeTouch Control
Duct Size6 inch