1
30" AND 36" ISLAND-MOUNT RANGE HOOD
Universal Installation Instructions and Use & Care Guide
For questions about features, operation/performance parts, accessories or service, call:
1-626-453-0550
or visit our website at...
www.akdytrading.net
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
Model: GVA-I
668I GVC-I
668IS2 GVA-IS2
610I 627I
688I

Questions and Answers

  • L
    Laura YoderAug 1, 2025
    Why is my AKDY GVA-I fan not working?
    • M
      Michael BerryAug 1, 2025
      There are a couple of reasons why the fan in your AKDY Ventilation Hood might not be working. It could be due to a malfunctioning electronic control caused by over voltage, in which case you should replace the control and user interface. Alternatively, the motor connector may have become loose during cleaning, causing a false contact in the main harness. To fix this, remove power supply from the hood, open the control box, and check that the connector from the motor is securely connected to the connector on the plastic, ensuring the locking system is engaged. If not, press the main connectors attached to the white plastic and push the motor/lamp connectors inward until the locking system is properly attached. Then, reconnect the hood to the power supply and test it.
  • T
    Theresa WilliamsNov 9, 2025
    What to do if AKDY GVA-I lamp does not turn on?
    • K
      klewisNov 9, 2025
      If the lamp on your AKDY Ventilation Hood isn't turning on, it could be due to several reasons. First, the electronic control might not be working due to over voltage; in this case, replace the control and user interface. Second, the lamp itself might be non-functional. Remove the lamp and check if the filament is burned or not correctly placed; replace the lamp if necessary. Finally, the motor connector may have become loose during cleaning, causing a false contact in the main harness. To resolve this, remove power supply from the hood, open the control box, and ensure the connector from the motor is securely connected to the connector on the plastic, making sure the locking system is well locked. If the connectors are not well connected: - Hold and press main connectors attached in the ...
  • L
    Lisa LewisNov 19, 2025
    How to fix noisy blower on AKDY GVA-I Ventilation Hood?
    • L
      Laura SchneiderNov 19, 2025
      A noisy blower in your AKDY Ventilation Hood can be caused by dirty filters or a false contact in the connectors. First, check if the grease and/or charcoal filters are clean. If they are dirty, replace the charcoal filter or wash the grease filter. If the filters aren't the issue, the problem might be a loose connection. To check this, remove power supply from the hood, open the control box, and verify that the connector coming from the motor is securely connected to the connector mounted in the plastic, ensuring the locking system is well locked. If the connectors are not well connected: - Hold and press main connectors attached in the white plastic. - Push inwards the motor/lamp connectors until the locking system on connectors is well attached. Reconnect the hood to the power supply...

Summary

RANGE HOOD SAFETY

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION REQUIREMENT

LOCATION REQUIREMENTS

Guidelines for choosing the optimal placement of the range hood.

INSTALLATION DIMENSIONS

Specifies crucial measurements for correct hood placement.

VENTING REQUIREMENTS

Details on how the vent system must be configured for proper operation.

ELECTRICAL REQUIREMENTS

INSTALLATION INSTRUCTIONS

INSTALL RANGE HOOD

Guidance on physically mounting the range hood assembly to the support structure.

RANGE HOOD USE

RANGE HOOD CONTROLS

Explanation of the various buttons and functions of the control panel.

TROUBLE SHOOTING

AKDY GVA-I Specifications

General IconGeneral
BrandAKDY
ModelGVA-I
CategoryVentilation Hood
LanguageEnglish