1
Trilogy Series
DL2800 Programming Instructions
OI246A 1/02ALARM LOCK
ALARM LOCK
ALARM LOCK
DL2800 Trilogy Series
Standalone Access Control System
PLUG IN THEN
ENTER YOUR CODE

Table of Contents

Other manuals for Alarm Lock DL2800

Question and Answer IconNeed help?

Do you have a question about the Alarm Lock DL2800 and is the answer not in the manual?

Summary

Features

Audit Trail - 1000 Events

Details about the audit trail log, its capacity, and how to view it.

User Features

Describes user code types, lockout modes, and groups supported by the lock system.

150 Scheduled Events

Explains programming for scheduled unlock/lock events and quick schedules.

Keypad and Download Programming

Covers programming methods via keypad or PC software.

AL-IR1 Infrared Printer

Describes the optional infrared printer for reports.

AL-DTM Data Transfer Module

Details the data transfer module for program data and audit trails.

Additional Features

Programmable Timeout Functions

Allows enabling/disabling users and passage mode for specific times.

Users Associated for more than one group

Explains managing users linked to multiple groups.

Service Code

Describes the one-time-use service code and its re-enabling.

Keypad Lockout

Configures lockout attempts and duration before keypad lockout.

Non-Volatile Memory

Confirms programming is stored persistently.

Error Checking

Mentions built-in error checking for programming.

Real Time Clock

Covers clock accuracy and adjustment features.

Advanced Features

Group 1 Member puts lock in Passage Mode

How a Group 1 member can enable passage mode within a time window.

Group 1 Member Enables Group 4 Users

How a Group 1 member enables Group 4 users within a time window.

Wiring and Power Up

Battery Replacement

Instructions for replacing the lock's batteries.

Wire Leads for DL2800 Models

Diagram and explanation of the lock's wire connections.

Power-Up - Retain Lock Programming

Steps to power up the lock while keeping programming intact.

Power-Up - Erase All Programming

Steps to power up and reset the lock to factory defaults.

Self Diagnostic Indications

Explains LED and beep codes for system status and errors.

Preliminary Information

Lock Operation

Basic lock operation principles and latch engagement.

Programming - Notes

Important notes and recommendations before programming.

LED Indications

Explains the meaning of different LED color and pattern indications.

Audible Indications

Lists sounds and their meanings for user feedback.

Programming Information

Details on programming authority levels and user hierarchies.

Getting Started

Battery Installation

Step-by-step guide for installing batteries.

Entering Program Mode

Instructions on how to access the programming mode.

Setting the Clock

Procedures for setting the date, time, and day of the week.

User Programming

Guides on adding basic user codes and potential code conflicts.

Exit Program Mode

How to safely exit the programming mode.

Print the Locks Time, Date and Day programming

Command to print clock settings.

Print the Locks User Code List

Command to print the list of programmed user codes.

Print the Locks Audit Trail

Command to print the audit log.

Methods of Programming

Keypad Programming

Overview of programming via the keypad interface.

Entering Program Mode

Details on entering the programming mode.

Program Mode

Description of the program mode indicators and timeout.

Exiting Program Mode

Methods for exiting the programming mode.

Downloading

How to program using PC software.

AL-DTM

Using the data transfer module with PC software.

Programming Functions

1. New Master Code

Steps to set or change the master code.

2. Add;Delete;Change User Codes

How to manage user codes, including types and associations.

Enabling;Disabling Users (By User Number)

Functions to enable or disable specific user codes.

3. Disable User

Function to disable a user code.

4. Enable User

Function to enable a user code.

5. User Enable with Timeout

Enables users for a specified duration.

User Lockout Mode

Manages lockout for all users except the master.

6. Enable Total User Lockout

Activates total lockout for all users.

7. Disable Total User Lockout

Deactivates total user lockout.

8. Change User Program Level Ability

Modifies user's ability to access programming functions.

9. Enable User 300 (Service Code)

Re-enables the service code for use.

10. Erase All Users Except the Master Code

Deletes all user codes except the master code.

12. Clear All Schedules and Timeout Functions

Resets all schedules and timeout functions.

13. Clear All Timeout Functions

Resets only timeout functions.

Enable;Disable Groups

Overview of functions to enable/disable user groups.

14. Disable Group 1

Disables Group 1.

15. Disable Group 2

Disables Group 2.

16. Disable Group 3

Disables Group 3.

17. Disable Group 4

Disables Group 4.

18. Disable All Groups

Disables all user groups.

19. Enable Group 1

Enables Group 1.

20. Enable Group 2

Enables Group 2.

21. Enable Group 3

Enables Group 3.

22. Enable Group 4

Enables Group 4.

23. Enable All Groups

Enables all user groups.

Group Disable;Enable with Timeout

Manages group status for a specified duration.

25. Timed Disable Group 1

Temporarily disables Group 1.

26. Timed Disable Group 2

Temporarily disables Group 2.

27. Timed Disable Group 3

Temporarily disables Group 3.

28. Timed Disable Group 4

Temporarily disables Group 4.

29. Timed Disable All Groups

Temporarily disables all groups.

30. Timed Enable Group 1

Temporarily enables Group 1.

31. Timed Enable Group 2

Temporarily enables Group 2.

32. Timed Enable Group 3

Temporarily enables Group 3.

33. Timed Enable Group 4

Temporarily enables Group 4.

34. Timed Enable All Groups

Temporarily enables all groups.

35. Add;Delete Group Association

Links or unlinks users to specific groups.

38. Set Date

Configures the lock's current date.

39. Set Time

Configures the lock's current time.

40. Set Day of Week

Sets the current day of the week.

Daylight Savings Time Enable;Disable

Manages daylight saving time adjustments.

41. Enable Daylight Savings

Activates daylight saving time.

42. Disable Daylight Savings

Deactivates daylight saving time.

Clock Adjust

Adjusts clock speed for accuracy.

43. Speed Up Clock

Sets the clock to run faster.

44. Slow Down Clock

Sets the clock to run slower.

Passage Mode Enable;Disable - Schedule will Override

Manages passage mode and its interaction with schedules.

45. Enable Passage Mode

Activates passage mode.

46. Disable Passage Mode

Deactivates passage mode.

47. Timed Passage Mode

Enables passage mode for a set duration.

Passage Mode Enable;Disable - Schedule will not Override

Manages passage mode where schedules do not override it.

48. Enable Passage Mode

Activates passage mode, not overridden by schedules.

49. Disable Passage Mode

Deactivates passage mode.

50. Return Lock to Normal Passage Mode Schedule

Restores lock to scheduled passage mode operation.

Pass Time

Sets how long the lock remains unlocked after code entry.

51. Set Pass Time to 5 Sec.

Sets unlock duration to 5 seconds.

52. Set Pass Time to 10 Sec.

Sets unlock duration to 10 seconds.

53. Set Pass Time to 15 Sec.

Sets unlock duration to 15 seconds.

55. Print Audit Trail

Prints the lock's audit trail log.

56. Print User Code List

Prints the list of programmed user codes.

57. Print Clock Settings and Software Version

Prints current clock settings and software version.

58. Upload;Download PC Data

Manages data transfer between lock and PC.

59. AL-DTM Door Number

Assigns a number to the lock for AL-DTM use.

60. Number of Attempt Before Lockout

Configures lockout after failed entry attempts.

61. Set the Attempts Lockout Time

Sets duration of keypad lockout.

Remote Input Disable;Enable

Manages the remote input function for door release.

64. Disable Remote Input

Disables the remote input feature.

65. Enable Remote Input

Enables the remote input feature.

Enter Key Enable;Disable

Allows programming codes matching first digits of other codes.

69. Enable as Enter Key

Activates the enter key function.

70. Disable as Enter Key

Deactivates the enter key function.

Scheduled Passage Mode Enable;Disable

Enables/disables passage mode based on schedule.

72. Schedule Enable Passage Mode (Unlock)

Schedules passage mode to be enabled (unlock).

73. Schedule Disable Passage Mode (Lock)

Schedules passage mode to be disabled (lock).

Scheduled Group Enable;Disable

Manages group enablement/disablement based on schedule.

74. Schedule Enable Group 1

Schedules Group 1 to be enabled.

75. Schedule Enable Group 2

Schedules Group 2 to be enabled.

76. Schedule Enable Group 3

Schedules Group 3 to be enabled.

77. Schedule Enable Group 4

Schedules Group 4 to be enabled.

78. Schedule Enable All Groups

Schedules all groups to be enabled.

79. Schedule Disable Group 1

Schedules Group 1 to be disabled.

80. Schedule Disable Group 2

Schedules Group 2 to be disabled.

81. Schedule Disable Group 3

Schedules Group 3 to be disabled.

82. Schedule Disable Group 4

Schedules Group 4 to be disabled.

83. Schedule Disable All Groups

Schedules all groups to be disabled.

Quick Schedules - Enable Group

Enables groups for predefined quick schedules.

84. Business Quick Schedule

Enables a group for business hours.

85. Day Quick Schedule

Enables a group for daytime hours.

86. Evening Quick Schedule

Enables a group for evening hours.

87. Night Quick Schedule

Enables a group for nighttime hours.

Scheduled Passage Mode (Group 1 Activated)

Passage mode activated by Group 1 user code within a window.

88. Passage Mode (Open Time Window)

Sets the start time for Group 1 passage mode activation.

89. Passage Mode (Close Time Window)

Sets the end time for Group 1 passage mode activation.

Scheduled Group 4 Enable (Group 1 Activated)

Enables Group 4 based on a Group 1 user code within a window.

92. Enable Group 4 (Open Time Window)

Sets the start time for Group 4 activation by Group 1.

93. Enable Group 4 (Close Time Window)

Sets the end time for Group 4 activation by Group 1.

99. Clear All Lock Programming and History LOG

Resets all programming and the audit log.

Using Advanced Features

Advanced User Programming

Examples of adding users to multiple groups.

Group 1 Activated Features

Explains how Group 1 activation affects other features.

Add a User to Group 1

Example of adding a user to Group 1.

Add Schedule that Opens the Lock (Passage Mode)

Example of scheduling passage mode activated by Group 1.

Manually close the Lock

Command to manually lock the door.

Automatically (Scheduled Lock) close the Lock

Command to schedule automatic locking.

ALARM LOCK LIMITED WARRANTY