These instructions deal with the installa-
tion and assembly of boiler and expan-
sion tank. Read these instructions care-
fully before assembling the boiler.
These instructions are approved for
The Alde Compact 3010 boiler tted in
caravans, motor caravans and buildings
in accordance with CE no. 0845 BP0003,
installation in vehicles e500 00005 and
EMC e5 03 0261.
Installation and repairs may only be carried
out by a professional. National regulations
must be adhered to.
TECHNICAL DATA
Measurements/Weight
Boiler height: 310 mm
Boiler depth: 340 mm
Boiler width: 510 mm
Weight: 14 kg (without uid)
Gas: Propane Butane
Output 1: 3,3 kW 3,8 kW
Consumption: 245 g/h 275 g/h
Output 2: 5,5 kW 6,4 kW
Consumption: 405 g/h 460 g/h
Pressure: I3+ 28-30/37 mbar
I3B/P 30 mbar
Volume/Pressure/Temp.
Liquid volume radiator water: 3,5 litre
Liquid volume warm water: 8,4 litre
Max pressure radiator water: 0,05 MPa
(0,5 bar)
Max pressure warm water: 0,3 MPa
(3,0 bar)
System temperature: max 85°C.
230 V ~
Output element: 1 x 1050 W
(2 or 3 kW) 1 x 2100 W
12 V DC
Current consump.: 1 amp (max)
Fuse: 3.15 amp+/3.15 amp-
INSTALLATION OF BOILER
The boiler can appropriately be located in
a wardrobe or storage space, but can also
be located under the oor of the vehicle.
If located outside the vehicle, the boiler
should be built into an enclosed space so
that it is protected against splashing of
water, exhaust gases, etc. In choosing the
location, consideration should also be given
to dismantling the service hatch (A 1) and
that space will be available for replacement
of components during service. The data
plate on the boiler shall be legible after
installation.
The measurements given in Fig. A for build-
ing in are recommended minimum meas-
urements with mounting of the boiler.
The space where the boiler is to be assem-
bled must be ventilated, with a ventilation
area of at least 70 cm2.
The boiler shall be screwed down onto the
oor through the holes in the xing brackets
(A 2).
NB ! The boiler must not be located in the
passenger area of a vehicle of type M2 or
M3 respectively.
Fig A.
Service panel1.
Holes for screwing down2.
MOUNTING OF ROOF FLUE
The boiler may only be mounted with the
original ue. The ue must not be blocked.
The roof ue should be mounted on a level
base, (however, a maximum of 30º roof
slope). Objects must not be mounted on
the roof within a radius of 200mm from the
ue.
Mark the centre of the location where the
ue is to be mounted, or drill a Ø 76mm
hole through the roof.
Mount the ue from the outside of the roof.
Seal between mounting washer (C 4) and
roof (C 5) with sealing compound for auto-
mobile body application, and screw down
the ue with 6 plate screws (C 6).
MOUNTING OF WALL FLUE
The boiler may only be mounted with the
original ue. The ue must not be blocked.
The wall ue should be mounted on as
at a surface as possible, and also so that
air can freely circulate past the ue. The
ue should not be mounted closer than
300mm sideways on from an opening
window or ventilation inlet.
A ue must not be mounted under a
window that can be opened, or a ventila-
tion inlet, see drawing.
If the ue is mounted closer than the
measurements given above, a window
circuit-breaker shall be installed that shuts
off the LPG gas supply when the window
is open. To guarantee the function of the
boiler, no object should be tted within a
radius of 300 mm around the chimney (no
ofcial claim).
NOTE that current national regulations
must be followed.
The distance from the ue to ventilation
inlet under the vehicle must be at least
300mm (not a legal requirement).
The distance from ue to relling posi-
tion or ventilation for fuel shall be at least
500mm.
Mark the place where the ue is to be
located. Then drill a Ø 83mm hole through
the outer wall. First mount the gasket (B
7) and then screw down the ue (B 8) with
the 6 plate screws (B 9). If the surface is
structured, of ball-hammered plate type,
sealing compound for automobile applica-
tion must be used with the gasket.
Note that the ue shall be mounted with
the bend upwards, (the roof ue is also
marked TOP OBEN). After that, mount the
plastic cap (B 10a) and the O ring (B 10b)
with the accompanying two screws (B 11).
Window
Prohibited zone
INSTALLATION INSTRUCTIONS COMPACT 3010

Other manuals for Alde Compact 3010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alde Compact 3010 and is the answer not in the manual?

Alde Compact 3010 Specifications

General IconGeneral
BrandAlde
ModelCompact 3010
CategoryBoiler
LanguageEnglish

Related product manuals