EasyManua.ls Logo

Allen-Bradley LSIG-MM - User Manual

Allen-Bradley LSIG-MM
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DIR 1000587R002 Version 02 140G-NTI-E12; 140G-NTK-E12; 140G-RTI-E30; 140G-RTK-E30
Bul. 140G/140MG
LSIG and LSIG-MM trip unit for 140G-N/ 140G-NS/ 140G-R
WARNING:
WARNUNG:
AVERTISSEMENT:
To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée.
Protéger le produit contre les environnements agressifs.
Desconéctese de la corriente eléctrica, antes de la instalación o
AVVERTENZA:
ADVERTENCIA:
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrent
e elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
Installation - Installazione - Instalación
Instalação - -
(Follow NFPA70E requirements).
(1)
DIR 1000587R0002 (Version 02)

Table of Contents

Questions and Answers

Allen-Bradley LSIG-MM Specifications

General IconGeneral
Trip UnitElectronic
StandardsIEC 60947-2
Protection FunctionsLong-time, Short-time, Instantaneous, Ground Fault
MountingFixed, Drawout
Communication OptionsOptional communication modules

Summary

Safety and Installation Warnings

LSIG Trip Unit Overview

Main Specifications

Key technical details including protections and functions.

Protections Defined

Details of the overload, short-circuit, and earth fault protections.

LSIG Trip Unit Specifications

LSIG Trip Unit User Interface

Dip Switch Settings

Configuration of tripping thresholds and time delays using dip switches.

LSIG Protection Functions

Protection L and S

Detailed description and settings for Protection L and Protection S.

LSIG Protection Function Details

Trip Curve Characteristics

Commissioning and Recommendations

Installation, Connections, and Checks

Steps for installing, connecting, and verifying trip unit setup.

Default Parameters

Predefined settings provided with the LSIG trip unit.

Troubleshooting Guide

Common Troubleshooting Scenarios

Table listing common issues and their potential causes and solutions.

Common Issues and Fault Scenarios

Table of typical situations, their causes, and suggested solutions.

Handling Faults and Unexpected Trips

Procedures for diagnosing and reporting trip unit malfunctions.

LSIG-MM Trip Unit Introduction

LSIG-MM Protections and Functions

List and description of available protections and functions for LSIG-MM.

LSIG-MM Technical Specifications

LSIG-MM User Menus

LSIG-MM Protection Functions

LSIG-MM Protection Function Details

LSIG-MM Advanced Protection Functions

LSIG-MM Special Protection Functions

Summary of Protection Functions

Protection Function Table and Tolerances

Comprehensive table summarizing protection functions, thresholds, and tolerances.

Trip Curve Graphs

Trip Recording and Measurements

Core Trip Unit Functions

Settings Menu Configuration

Test Menu Procedures

Putting into Service and Recommendations

Default Parameters Configuration

Review and adjustment of predefined trip unit operating parameters.

Troubleshooting and Accessories

Fault Handling and Accessory Overview

Recommendations for handling faults and introduction to accessories.

Related product manuals