EasyManua.ls Logo

Allen-Bradley LSIG - User Manual

Allen-Bradley LSIG
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DIR 1000587R002 Version 02 140G-NTI-E12; 140G-NTK-E12; 140G-RTI-E30; 140G-RTK-E30
Bul. 140G/140MG
LSIG and LSIG-MM trip unit for 140G-N/ 140G-NS/ 140G-R
WARNING:
WARNUNG:
AVERTISSEMENT:
To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée.
Protéger le produit contre les environnements agressifs.
Desconéctese de la corriente eléctrica, antes de la instalación o
AVVERTENZA:
ADVERTENCIA:
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrent
e elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
Installation - Installazione - Instalación
Instalação - -
(Follow NFPA70E requirements).
(1)
DIR 1000587R0002 (Version 02)

Table of Contents

Questions and Answers:

Allen-Bradley LSIG Specifications

General IconGeneral
CategoryCircuit Breakers
BrandAllen-Bradley
DescriptionElectronic trip circuit breaker with Long-time, Short-time, Instantaneous, and Ground-fault protection
Protection FunctionsLong-time (L), Short-time (S), Instantaneous (I), Ground-fault (G)
Voltage RatingTypically 600V AC or higher, depending on model
Current RatingVaries by model (e.g., 15A to 5000A)
Breaking CapacityVaries by model and voltage rating
StandardsUL, IEC

Summary

General Safety Precautions

Installation Safety Warnings

Disconnect power before installation/servicing to prevent electrical shock.

Trip Unit Functional Comparison

Compatibility between Trip Units and CB

Details compatibility between LSIG/LSIG-MM trip units and circuit breakers.

Abbreviations Used

Lists and defines abbreviations used in the document.

Safety Notes and Dielectric Tests

Crucial safety information and notes for dielectric tests.

LSIG Trip Unit Overview

Unit Introduction and Specifications

Basic introduction, main specifications, and components of the LSIG trip unit.

Protection Functions

Lists the protection capabilities of the LSIG trip unit.

Available Functions

Describes the various functions integrated into the LSIG trip unit.

LSIG Trip Unit Specifications

CB Compatibility and Standards

Details compatibility with circuit breakers and relevant international standards.

Environmental and Electrical Characteristics

Outlines operating conditions and electrical power requirements.

LSIG Trip Unit User Interface

Interface Elements and Dip Switches

Describes the physical interface, including dip switches for configuration.

LSIG Trip Unit Interface Details

LED Indicators and iTest Button

Explains the meaning of LEDs and the functionality of the iTest button.

Test Connector and Protection Functions Overview

Details the test connector and introduces protection functions.

Protection Functions

General Protection Overview

Provides a high-level introduction to protection functions.

Protection Functions

Protection L, S, I, and G Details

In-depth explanation of the L, S, I, and G protection functions.

Protection Functions

Neutral Protection and linst Protection

Configuration for neutral protection and instantaneous short-circuit protection.

Summary Table of Protections

Comprehensive table summarizing all protection functions.

Trip Curve Characteristics

L-S Trip Curve Examples

Illustrates trip curves for L-S functions with different time settings.

Main Functions

Measurement and Self-Monitoring

Covers measurement capabilities and self-testing features.

Installation and Recommendations

Installation, Connections, and Defaults

Guides on installation, connections, checks, and default settings.

Troubleshooting Guide

Troubleshooting Table and Fault Handling

Provides solutions for common issues and guidance for faulty units.

LSIG-MM Trip Unit Introduction

Unit Overview and Specifications

Introduces the LSIG-MM unit, its interface, and general specifications.

LSIG-MM Protections and Functions

Details the protection types and operational functions of the LSIG-MM unit.

LSIG-MM Specifications Details

Compatibility, Standards, and Characteristics

Covers CB compatibility, standards compliance, and environmental/electrical traits.

LSIG-MM User Interface

Interface Elements and LED Indicators

Describes the display, LEDs, and their meanings.

LSIG-MM Interface Operations

Push-buttons and Display Modes

Explains the function of push-buttons and the display's operating modes.

LSIG-MM Interface Information

Graphic Ammeter and Alarms

Details the graphic ammeter display and alarm messages.

LSIG-MM User Menus

Operating Icons and Menu Access

Describes operating icons and how to access user menus.

LSIG-MM Menu Navigation

Menu Area Structure and Browsing

Explains the menu tree structure and how to navigate and edit parameters.

LSIG-MM Protection Functions

Protection Operation and L Function

Covers general protection operation notes and detailed explanation of Protection L.

LSIG-MM Protection Functions

Thermal Memory and Protection S

Details thermal memory functions, Protection S, and start-up threshold.

Protection I and G Details

Explains Protection I and Protection G.

LSIG-MM Protection Functions

Protection G, U, and T

Explains Protection G, U (Unbalance), and T (Temperature).

LSIG-MM Protection Functions

Load Control, Neutral, MM, and linst

Covers Load Control, Neutral Protection, MM, and linst protections.

Protection Functions Summary

Summary Table of Protection Functions

A comprehensive table summarizing all protection functions, thresholds, and times.

Trip Curve Characteristics

L-S Trip Curves

Illustrates trip curves for L-S functions with different time curve settings.

Trip Curve Characteristics

L IEC 60255-121 Type A Curves

Displays trip curves for function L according to IEC 60255-121 standards (Types A, B).

Trip Curve Characteristics

L IEC 60255-121 Type C Curves

Shows trip curves for function L (IEC 60255-121 Type C) and function G.

Measuring Functions

Runtime Measurements and Tolerances

Details runtime measurements for currents and their operational tolerances.

Measuring Functions

Trip Logs and Event Records

Covers trip logs, event recording, and the measurements log register.

Peak Factor and Contact Wear

Details peak factor measurement and contact wear monitoring.

Main Functions

Watchdog, CB State, and MM Function

Explains watchdog functions, CB state monitoring, and Function MM.

Settings Menu Configuration

Circuit-breaker, Frequency, and Interval Settings

Details settings for circuit-breaker, network frequency, and measurement interval.

System and Display Settings

Covers system settings like language/password and display contrast.

Settings Menu Options

System Settings (Language, Password)

Covers system settings like language/password.

Display Contrast Adjustment

Covers display contrast adjustment.

Test Menu Procedures

Autotest, Trip Test, and MM Test

Guides on performing unit tests.

Installation and Recommendations

Installation, Uninstalling, and Connections

Provides procedures for installation, uninstallation, and connection guidelines.

Default Parameters

Predefined Protection Settings

Lists the default parameters for protections, language, and frequency.

Troubleshooting Guide

Troubleshooting Scenarios and Fault Handling

Offers solutions for common issues and guidance for diagnosing faults.

Accessories

External Neutral, Rating Plug, and Battery Unit

Describes optional accessories like external neutral sensor, rating plug, and battery unit.

Related product manuals