EasyManuals Logo

Allen-Bradley PowerFlex 520 Series User Manual

Allen-Bradley PowerFlex 520 Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
Rockwell Automation Publication 520-UM001G-EN-E - September 2014 127
Programming and Parameters Chapter 3
Advanced Program Group (continued)
A562 [Find Home Freq]
PowerFlex 525 only.
Sets the maximum frequency the drive uses when “Find Home” is issued.
Values Default: 10.0 Hz
Min/Max: 0.1/500.0 Hz
Display: 0.1 Hz
PF 525
A563 [Find Home Dir]
Stop drive before changing this parameter.
PowerFlex 525 only.
Sets the direction the drive commands when “Find Home” is issued.
Options 0“Forward (Default)
1“Reverse
PF 525
A564 [Encoder Pos Tol]
PowerFlex 525 only.
Sets the “At Position” and the “At Home’ tolerance around the encoder count. The value is added to and subtracted from the target encoder unit value to create the tolerance range.
Values Default: 100
Min/Max: 1/50000
Display: 1
PF 525
A565 [Pos Reg Filter]
PowerFlex 525 only.
Sets the error signal filter in the position regulator.
Values Default: 8
Min/Max: 0/15
Display: 1
PF 525
A566 [Pos Reg Gain]
PowerFlex 525 only.
Sets the gain adjustment for the position regulator.
Values Default: 3.0
Min/Max: 0.0/200.0
Display: 0.1
PF 525

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 520 Series and is the answer not in the manual?

Allen-Bradley PowerFlex 520 Series Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 520 Series
CategoryDC Drives
LanguageEnglish

Related product manuals