Interpret the Attribute Tables
Chapter 3
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018 105
Attr. ID Access
Rule
Tag Attribute Name B E F P V T C/D Conditional
Implementation
1322 Set
Motor Overload Limit - - O O O O Yes
695 Set
Motor Overspeed User Limit - - O O O O Yes
694 Set
Motor Phase Loss Limit - - O O O O Yes V26
1317 Set
Motor Polarity - - O O O O Yes
1319 Set
Motor Rated Continuous Current - - R R R R Yes
1321 Set
Motor Rated Output Power - - C C C C Yes O-PM; R-IM
1320 Set
Motor Rated Peak Current - - C C C C Yes R-PM; O-IM
1318 Set
Motor Rated Voltage - - R R R R Yes
1000 Get
Motor Test Bus Overvoltage Speed - - R R R R
IPM Motor Only, V29
1001 Get
Motor Test Commutation Offset Comp - - R R R R
IPM Motor Only, V29
174 Get
Motor Test Counter EMF - - R R R R
PM Motor only
172 Get
Motor Test Flux Current - - R R R R
Ind Motor only
171 Get
Motor Test Inductance - - R R R R
999 Get
Motor Test Ld Flux Saturation - - R R R R
IPM Motor Only, V29
997 Get
Motor Test Ld Inductance - - R R R R
IPM Motor Only, V29
998 Get
Motor Test Lq Flux Saturation - - R R R R
IPM Motor Only, V29
996 Get
Motor Test Lq Inductance - - R R R R
IPM Motor Only, V29
170 Get
Motor Test Resistance - - R R R R
173 Get
Motor Test Slip Speed - - R R R R
Ind Motor only
175 Get
Motor Test Status - - R R R R
697 Set
Motor Thermal Overload User Limit - - O O O O Yes
1315 Set
Motor Type - - R R R R Yes Optional Enumeration
1316 Set
Motor Unit - - R R R R Yes
1325 Set
Motor Winding To Ambient Capacitance - - O O O O Yes
1326 Set
Motor Winding To Ambient Resistance - - O O O O Yes
521 Get T Operative Current Limit - - O O O O Yes F Support in V29
14 Get
Output Cam Execution Targets - R R R R R
E
38 Get T Output Cam Lock Status - R - R R R
E
37 Get T Output Cam Pending Status - R - R R R
E
36 Get T Output Cam Status - R - R R R
E
39 Get T Output Cam Transition Status - R - R R R
E
601 Get T Output Current - - R R R R Yes
600 Get T Output Frequency - - R O O O Yes
603 Get T Output Power - - R R R R Yes
602 Get T Output Voltage - - R R R R Yes
508 Set
Overtorque Limit - - O O O O Yes
509 Set
Overtorque Limit Time - - O O O O Yes
1082 Get
Planner Actual Position - R R R R R
V30
1081 Get
Planner Command Position - Fractional - - R R R -
V30
1080 Get
Planner Command Position - Integer - - R R R -
V30

Table of Contents

Other manuals for Allen-Bradley PowerFlex 527

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 527 and is the answer not in the manual?

Allen-Bradley PowerFlex 527 Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 527
CategoryController
LanguageEnglish

Related product manuals