Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015 17
Setting up the 42EF for IO-Link Mode
Chapter 4
Setting up the 42EF for IO-Link Mode
This chapter shows the physical hardware and software required to configure the
42EF through IO-Link and provides a simple guide to setting up the hardware.
Products required:
Hardware
42EF RightSight sensor
CompactLogix™ or ControlLogix® PLC Platform
POINT I/O™ Communications Interface: 1734-AENTR
POINT I/O IO-Link Master Module: 1734-4IOL
POINT I/O Terminal Base: 1734-TB
RJ45 network cable for EtherNet/IP connectivity:
1585J
-M8TBJM-1M9*
889D cordsets (optional): 889D-F4AC-5** (IO-Link maximum
acc
eptable cable length is 20 m (65.6 ft))
Software
Studio 5000 environments, version 20 and higher
Sensor specific IODD
1734-4IOL IO-Link Add-on Profile (AOP)