Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015 55
Device Parameters
Observation Tab
Parameter Name
Index
Hex(Dec)
Sub-Index
Hex (Dec) Access Default Allowed Value Data Type (Length )
Device Monitoring
.SignalStrength On 0x56(86) 0x01(1) RO - 0-65,535
UIntegerT(RecordT)
bitLength=16
bitOffset=16
.SignalStrength Off 0x56(86) 0x02(2) RO - 0-65,536
UIntegerT(RecordT)
bitLength=16
bitOffset=0
Contrast 0x57(87) 0x00(0) RO - 0-255
UIntegerT
bitLength=8
Excess Gain 0x59(89) 0x00(0) RO - 0-255
UIntegerT
bitLength=8
Gain (only for 42EF polarized
r
e
troreflective)
0x59(89) 0x00(0) RO - 0-255
UIntegerT