58 Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015
Device Parameters
Diagnostic Tab
Parameter Name
Index
Hex(Dec)
Sub-Index
Hex (Dec) Access Default Allowed Value Data Type (Length )
Device Access Locks
Device Access Locks.Parameter (Write) Access
Loc
ks
0x0C(12) 0x00(0) RO 0=False 0=False
Boolean(RecordT)
bitOffset=0
Device Access Locks.Data Storage Lock 0x0C(12) 0x01(1) RO 0=False 0=False
Boolean(RecordT)
bitOffset=1
Device Access Locks.Local Parameterization Lock 0x0C(12) 0x02(2) RW 0=False
0=False
1=True
Boolean(RecordT)
bitOffset=2
Service Function
<Standard Command> Device Reset 0x02(2) 0x00(0) WO
Button = "Device Reset"
Button = 128
Button = "Device Reset"
Button = 128
<Standard Command> Restore Factory Settings 0x02(2) 0x82(130) WO
Button = "Restore
Fa
c
tory Settings"
Value = 130
UIntegerT
bitLength=8
.Locator Indicator 0x5E(94) 0x01(1) RW 0= Disabled
0 = Disable(d)
1 = Enable(d)
Uinteger(RecordT)
bitLength=8
bitOffset=8
.LEDs Enable 5E(94) 0x0(2) RW 1= Enabled
0 = Disable(d)
1 = Enable(d)
Uinteger(RecordT)
bitLength=8
bitOffset=0
Device Status
Alignment Mode 0x5F(95) 0x00(0) RW 0= Disabled
0 = Disable(d)
1 = Enable(d)
UIntegerT
bitLength=8
Error Count 0x20(32) 0x00(0) RO - -
UIntegerT
bitLength=16
Device Status 0x24(36) 0x00(0) RO '0 = Device is OK
0 = Device is OK
1 = Maintenance
re
quired
2 = Out of specification
3 = Funtional chek
4 = Failure
UIntegerT
bitLength=8
Last Event 0x6E(110) 0x00(0) RO 0 0-65,535
UIntegerT
bitLength=16
Operation Information
.Operating Time - Since Inception 0x5B(91) 0x01(1) RO
Uinteger(RecordT)
bitLength=32
bitOffset=32
.Operating Time - Since Power Up 0x5B(91) 0x0(2) RO
Uinteger(RecordT)
bitLength=32
bitOffset=0