Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015 57
Device Parameters
Parameter Tab (continued)
Parameter Name
Index
Hex(Dec)
Sub-
Index
Hex (Dec) Access Default Allowed Value Data Type (Length )
Timer
.Mode 0x5C(92) 0x01(1) RW 0 = Disabled
0 = Disabled
1 = Enabled
Uinteger(RecordT)
bitLength=8
bitOffset=40
.Reset 0x5C(92) 0x02(2) WO - 1 = Reset
Uinteger(RecordT)
bitLength=8
bitOffset=32
.DurationTriggered 0x5C(92) 0x03(3) RO 0 0-4,095
Uinteger(RecordT)
bitLength=12
.DurationNotTriggered 0x5C(92) 0x04(4) RO 0 0-4,095
Uinteger(RecordT)
bitLength=12
Data Mapping Cofiguration
.Mode 0x50(80) 0x01(1) RW
0 =
T
riggered,Margin,
Proximity,Gain,Si
gnal,
0 =
Tr
iggerMarginLowAlarmProximityAlarmExcessGainLevel
ReceivedSignalStrength,
1 =
Tr
iggerMarginLowAlarmProximityAlarmExcessGainLevel
ContrastLevelTemperature,
2 =
TriggerMarginLowAlarmProximityAlarmExcessGainLevel
CounterValue,
3 = TriggerMarginLowAlarmProximityAlarmOnDurationOff
Duration
Uinteger(RecordT)
bitLength=8
bitOffset=0