56 Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015
Device Parameters
Parameter Tab
Parameter Name
Index
Hex(Dec)
Sub-Index
Hex (Dec) Access Default Allowed Value Data Type (Length )
User Interface Configuration
Operation Configuration
Triggered1(or Triggered)
.Set Point - Threshold 0x3C(60) 0x01(1) RW
1000
505-12923
Uinteger(RecordT)
bitLength=16
bitOffset=16
.Polarity
0x70(112)
0x01(1) RW 1= Inverted
0 = Not Inverted,
1 = Inverted
Boolean (RecordT)
bitLength=48
bitOffset=40
.Hysteresis 0x3D(61) 0x03(3) RO 1650
Uinteger(RecordT)
bitLength=16
bitOffset=0
Pin 2 Mode 0x60(96) 0x00(0) RW 0 = Disabled
0 = Disabled
1 = Light Operate
2 = Dark Operate
Uinteger
bitLength=8
Sensor Configuration
.MarginLevel - Low Multiplier 0x58(88) 0x01(1) RW
4 = 0.8
0 = 0.5
1 = 0.6
2 = 0.6
3 = 0.7
4 = 0.8
Uinteger(RecordT)
bitLength=8
bitOffset=8
.MarginLevel - High Multiplier 0x58(88) 0x02(2) RW 1 = 1.5
0 = 1.0
1 = 1.5
2 = 2.0
3 = 5.0
4 = 10.0
5 = 15.0
6 = 20.0
Uinteger(RecordT)
bitLength=8
bitOffset=0
Counter/Timer
Counter
Mode 0x5D(93) 0x01(1) RW
0 = Disabled
0 = Disabled
1 = Enabled
Uinteger(RecordT)
bitLength=8
bitOffset=24
.Reset 0x5D(93) 0x02(2) WO - 1 = Reset
Uinteger(RecordT)
bitLength=8
bitOffset=16
.Counter 0x5D(93) 0x03(3) RO 0 0-65,535
Uinteger(RecordT)
bitLength=16
bitOffset=0