Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015 59
Device Parameters
Diagnostic Tab (continued)
Parameter Name
Index
Hex(Dec)
Sub-Index
Hex (Dec) Access Default Allowed Value Data Type (Length )
Temperature
.Actual - Since Power Up 0x5A(90) 0x01(1) RO - -40 - 125
IntegerT(RecordT)
bitLength=8
bitOffset=32
.Maximum - Since Power Up 0x5A(90) 0x02(2) RO - -40 - 125
IntegerT(RecordT)
bitLength=8
bitOffset=24
.Maximum - Since Inception 0x5A(90) 0x02(3) RO - -40 - 125
IntegerT(RecordT)
bitLength=8
bitOffset=16
.Minimum Since Power Up 0x5A(90) 0x04(4) RO - -40 - 125
IntegerT(RecordT)
bitLength=8
bitOffset=8
.Minimum - Since Inception 0x5A(90) 0x05(5) RO - -40 - 125
IntegerT(RecordT)
bitLength=8
bitOffset=0
Communication Characteristics
Direct Parameters 1.Min Cycle Time 0x00(0) 0x03(3) RO
20 2 ms
UIntegerT
bitLength=8
bitOffset=104
Direct Parameters 1. Master Cycle Time 0x00(0) 0x02(2) RO
20 2 ms
UIntegerT
bitLength=8
bitOffset=112
Direct Parameters 1.IO-Link Revision ID 0x00(0) 0x05(5) RO
0x11
UIntegerT
bitLength=8
bitOffset=88