Rockwell Automation Publication 42EF-UM001A-EN-P - September 2015 41
Exploring the 42EF IO-Link Parameters
Diagnosis Tab
The Diagnosis Tab is divided into five sections:
Device Access Locks,
Service Function,
Operating Information,
Tem p er a ture , a n d
Communications Characteristics
De
vice Access Locks: This
section displays the Device Storage Lock and the
user Interface Lock parameters. The Device Storage Lock is a read only
parameter that describes that data storage on the sensor cannot be locked and the
Local User Interface Lock keeps unauthorized operators from changing the
sensor threshold setting when using the local sensitivity adjustment (when
available).
Service Function: This
section contains multiple parameters that allow
operators to enable additional sensing functionality. This parameter can only be
accessed through explicit messages as described in Chapter 11.
Restore Factory Settings: This
is a write only command and sets the current
sensor settings to their factory default values. This parameter can only be
accessed via explicit message as defined in Chapter 11.
Device Reset: This
is a write only command that performs the same function as
cycling power in the sensor.