28 M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 5
TMB1336P
INSTANT
ELECTRONIC
IGNITION
CONTROL
LIGHTS
THERMOSTAT
ATTACHING
SCREW
THERMOSTAT
KNOB
REVERSING/NONREVERSING
SWITCH
PROBE
THERMOSTAT
TUBE
CONTACT
BLOCK
EMERGENCY STOP
BUTTON
TEMPERATURE
GRAPHIC
PANEL