46 M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
61. CYLINDER DRIVE MOTOR
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler. Refer
to Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Remove drive belt.
d. Mark location of motor on the motor mounting
bracket and remove screws and nuts holding
motor to mounting bracket. Refer to Figure 22.
e. Disconnect wire harness from motor.
f. Remove motor pulley.
NOTE: Refer to wiring diagram when rewiring the
motor.
g. After installing motor, adjust cylinder belt and
drive belt.
Figure 22
T237PE3E
ATTACHING
SCREW
MOTOR
MOTOR
PULLEY
MOTOR
MOUNTING
BRACKET
ATTACHING
NUT

Table of Contents