To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Section 3
Troubleshooting
IMPORTANT: Refer to appropriate wiring diagram for aid in testing tumbler components.
1. MOTOR DOES NOT START
POSSIBLE CAUSE TO CORRECT
Electrical power off, blown control fuse or circuit
breaker tripped.
Check power supply, reset breaker, or replace fuses.
Inoperative transformer. Replace transformer.
Loading door not closed or inoperative door switch. Close door, or test switch and replace if inoperative.
Door switch improperly adjusted. Refer to Adjustment Section in this manual for door
switch adjustment.
Trunnion bearings binding. Replace trunnion bearings.
Start circuit not completed. Press start switch, or test switch and replace if
inoperative.
Idler shaft binding. Replace bearings.
Inoperative motor. Have motor tested and replace if inoperative.
Inoperative relay. Replace relay.
Timer improperly set. Turn drying timer clockwise to desired setting.
Inoperative timer. Test timer and replace if inoperative.
Broken, loose or incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.