BASIC SETTINGS
Display Description Default
Screen Saver Enable/Disable Disable
Display Power Save Enable/Disable Enable
BACKLIGHT BRIGHTNESS
During User Interaction 0-255 230
While Running 0-255 190
While Idle 0-255 128
Audio Signal Set instances when the machine sounds a tone.
Button Pressed Enable/Disable Disable
Start Mode / Mimic Quantum Enable/Disable Disable
Serial Vend / Network Vend Enable/Disable Disable
Coin Vend / Card Vend / Start Pulse Vend Enable/Disable Disable
End of Cycle Enable/Disable Disable
Time Display Format MM or MM:SS
Cycle Complete Timer Enable/Disable Enable
Table 3
Machine Settings
Default values marked as * are customized at the factory accord-
ing to the machine's specific market and model.
MACHINE SETTINGS
Display Description Default
Machine Configuration View the configuration parameters of the ma-
chine.
Supply Voltage 120 Enable/Disable *
Approach Screen Enable/Disable Enable
Custom Approach Message "Edit", keyboard Dryer Ready
Errors Set errors to appear or be hidden on the display.
Coin Error Enable/Disable
Enabled / Disabled Enable/Disable Enable
Penalty Enable/Disable Disable
Vend Header Present Error Enable/Disable Enable
Table 4  continues...