Gas Requirements
70
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
8,001-10,000
( 2,441-3,050)
36 0.1065 (2.7) M411375 30,600 (32)
2,001-4,000
(610-1,220)
30 0.1285 (---) M401021 48,300 (51)
4,001-6,000
( 1,221-1,830)
1/8 0.1250 (3.2) M402489 44,100 (47)
6,001-8,000
(1,831-2,440)
31 0.1200 (3.0) M401017 39,900 (42)
Natural
Gas 60
Hz
8,001-10,000
(2,441-3,050)
33 0.1130 (2.9) M401022 35,700 (38)
2,001-4,000
( 610-1,220)
--- 0.1299 (3.3) 44253801 48,300 (51)
4,001-6,000
(1,221-1,830)
1/8 0.1250 (3.2) M402489 44,100 (47)
6,001-8,000
( 1,831-2,440)
--- 0.1220 (3.1) 70070903 39,900 (42)
Natural
Gas 50
Hz
8,001-10,000
( 2,441-3,050)
32 0.1160 (2.9) M402444 35,700 (38)
2,001-4,000
( 610-1,220)
--- 0.1299 (3.3) 44253801 50,600 (53)
4,001-6,000
( 1,221-1,830)
1/8 0.1250 (3.2) M402489 46,200 (49)
6,001-8,000
( 1,831-2,440)
--- 0.1220 (3.1) 70070903 41,800 (44)
030 Series
Natural
Gas 60
Hz
8,001-10,000
(2,441-3,050)
31 0.1200 (3.0)
1
M401017 37,400 (39)

Table of Contents