Electrical Requirements
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 95
Nonreversing Reversing Breaker Rating Wire Size AWG
(mm
2
)
208V/60Hz/1ph L1, L2, Neutral,
and ground
129 N/A 175A – 2 pole 2/0 (70)
240V/60Hz/1ph L1, L2, Neutral,
and ground
115 N/A 150A – 2 pole 1/0 (50)
200V/60Hz/1ph L1, Neutral, and
ground
122 N/A 175A – 1 pole 2/0 (70)
200V/50Hz/1ph L1, Neutral, and
ground
131 N/A 175A – 1 pole 2/0 (70)
230-240V/50Hz/1ph L1, Neutral, and
ground
119 N/A 150A – 1 pole 1/0 (50)
200-208V/60Hz/3ph L1, L2, L3, and
ground
79 79 100A* – 3 pole 3 (26.7)
240V/60Hz/3ph L1, L2, L3, and
ground
65 65 80A* – 3 pole 4 (25)
380V/50Hz/3ph L1, L2, L3, and
ground
43 43 60A* – 3 pole 6 (16)
400-415V/50Hz/3ph L1, L2, L3, and
ground
38 38 50A* – 3 pole 6 (16)
* 3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable
Table 25