806221 17
General Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must
be
re
connected to ensure that the washer is properly grounded.
Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
4. Dipswitch Configuration
*Switch 2
When set to OFF, energy saving water and fill levels are used for the specific type/region of the machine. When set
to ON, energy saving cycle settings are not used.
**Switch 3
When set to OFF, the Default Water Levels are used. When set to ON, the owner can increase the water level using
the Extra Water Mode. Higher water levels are not recommended as they may result in water leaking from the
machine door.
OFF ON
Switch 1 120 Volt AC Supply 240 Volt AC Supply
Switch 2* Energy Saving Cycles Standard Cycles
Switch 3** Default Water Level Increased Water Level
Switch 4
Leak and Slow Drain Errors Off
Leak and Slow Drain Errors
On
Switch 5 Unused Unused
Switch 6 Cool Down Disabled Cool Down Enabled
Switch 7 Heater Disabled Heater Enabled
Switch 8 Electric Pump Gravity Drain
Tab le 7