78 806221
Dryer Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must
be
re
connected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
43. Fabric Selector Switch
NOTE: Refer to proper model wiring diagram
when rewiring switch.
a. Set test meter to read Ohms and apply mete
r
probes to switch termi
nals.
NOTE: Refer to proper model wiring diagram
when reconnecting wires.
FABRIC SELECTOR SWITCH – 4 Position
L1-1 L1-2
Fluff – –
Delicate X X
Perm. Press – X
Normal – X
X indicates closed
FABRIC SELECTOR SWITCH
– 3 Position
L1-2 L1-3 L1-1
Fluff (No Heat) – X –
Delicate X – X
Perm. Press X – –
Normal (Regular) X – –
X indicates closed