www.alliancelaundry.com
Programming
Topload Washer
Refer to Page 4 for Model Numbers
TLW14C
TLW5R
Part No. 202065R6
May 2014
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Question and Answer IconNeed help?

Do you have a question about the ALLIANCE HWNLX2SP111CW01 and is the answer not in the manual?

ALLIANCE HWNLX2SP111CW01 Specifications

General IconGeneral
BrandAlliance
ModelHWNLX2SP111CW01
CategoryWasher
Loading TypeFront Load
ColorWhite
Voltage120V
Frequency60 Hz
Amperage15 A
Control TypeElectronic
Height43 inches
Cycle OptionsNormal, Delicate
Water Level OptionsLow, Medium, High
MaterialStainless Steel
Warranty3 year limited warranty

Summary

Preliminary Information

About the Control

Control unit for cycle selection, temp, vend prices, and diagnostics.

Glossary of Terms

Defines key terms and abbreviations used throughout the manual.

Power Failure Recovery

Describes how the washer resumes or ends cycles after power interruptions.

Communications

Outlines methods for programming and data retrieval via various devices.

Infra-red Communications (Optional)

Program/read data using external devices like PDAs.

Serial Card Reader Communications (Card Models Only)

Vending transactions and audit collection via card readers.

Network Communications

Link control to PC for programming and data collection.

Model Identification

Control Identification

Select Cycle Pads

Pads used to select the specific washer cycle and cycle modifiers.

Select Wash Temp Pads

Pads used to select water temperature for wash and rinse fills.

Display Identification

Light Emitting Diodes (LEDs)

LEDs indicating chosen cycle, temperature, and status.

Four 7-Segment Digits

Display for time, price, error messages, and descriptive codes.

Washer Operation

Start Up

Initial display and mode entry upon power application.

Ready Mode

How to start cycles and select options before the first fill.

Cycle Sequence

Control indicates cycle progress and handles coin entry.

Opening the Washer Lid

How opening the lid affects the cycle and display.

Special Features

Programming Control

Allows owners to program cycles, vend prices, and features.

Collecting Audit Information

How to retrieve stored data like coin counts and cycle totals.

Testing Machine and Control Functions

Details how to run specific diagnostic tests on the washer.

Opening the Service Door

Coin Models

Accessing programming and diagnostics for coin-operated models.

Card Reader Models

Accessing programming and diagnostics for card reader models.

Entering the Manual Mode

How to Enter the Manual Mode

Step-by-step instructions to access programming and diagnostic modes.

Programming Control

What Can Be Programmed?

Overview of programmable parameters like cycle settings and vend pricing.

Programmable Options Available

List of all available options with display codes, defaults, and ranges.

Vend Price #1 “AtS1”

Sets the vend price for a normal/hot wash cycle.

Coin #1 Value “dEn1”

Sets the numerical value for the first coin type used for payment.

Coin #2 Value “dEn2”

Sets the numerical value for the second coin type used for payment.

Start Pulse Mode “PLSn”

Configures single or multiple pulses to start the cycle.

Default Cycle “dCYC”

Sets the default cycle and temperature displayed in Ready Mode.

OPL Mode Enable/Disable “oPL”

Enables/disables OPL mode where no vend price is needed.

Audio Signal “Aud”

Programs when the signal sounds for various events.

Error Code Programming “Err-”

Allows enabling or disabling specific errors in the control.

Set Real-Time Clock “rtC-”

Allows setting the internal clock to the correct time and date.

Special Vend A Data “SPA-”

Sets the day(s) of the week for a special vend.

Cycle Modifier Programming “CnP”

Programs cycle modifiers like extra wash/rinse time or warm rinse.

Cycle Programming “CP--”

Sets the time duration for various steps within each cycle.

Drop Off Mode (On/Off) “droP”

Limits machine use to attendants without requiring payment.

Power Fail Reset “PFr”

Sets duration control stores cycle info during power failures.

Manual Rapid Advance (On/Off) “rAEn”

Enables/disables feature to quickly advance through cycles.

Manual Diagnostics (On/Off) “dAEn”

Enables or disables the manual diagnostics option.

Production Test Cycle (On/Off) “PtEn”

Enables or disables access to the production test cycle.

Collecting Audit Information

How to Enter Audit Feature

Details methods to access and view stored audit data.

How to Read Audit Data

Explains how to interpret and view retrieved audit information.

How to Exit Audit Feature

Instructions for safely exiting audit data retrieval mode.

Testing Machine and Electronic Control Functions

How to Enter Testing Feature

Guide to accessing the diagnostic test mode.

How to Start Tests

Instructions on initiating specific diagnostic tests from the chart.

How to Exit Testing Feature

Procedures for exiting diagnostic tests and returning to previous mode.

Diagnostic Test Descriptions

Detailed explanations of each available diagnostic test.

Manual Reset

How to Enter Manual Reset

Steps to reset the washer control to factory default settings.

Error Codes

Rapid Advance Feature

How to Enter Rapid Advance from Ready Mode

Steps to activate rapid advance when machine is in Ready Mode.

How to Enter Rapid Advance During an Active Cycle

Steps to activate rapid advance when a cycle is running.

How to Exit Rapid Advance Feature

Instructions for exiting the rapid advance mode.

Clear Vend Feature

How to Clear Vend

Resets control to ready mode when a vend price is partially satisfied.

Power Fail Recovery

Power Fail Reset Disabled

Explains default behavior when power fails and is restored.

Power Fail Reset Enabled

Describes how programmed reset times affect cycle continuation.

Communications Mode

Infra-red Communications

Enables communication with external devices for programming/data reading.

Card Reader Communications (Card Models Only)

Allows communication with card reader for vending and data.

Network Communications

Enables communication with a network for programming and data.

Default Cycle Time