PAGE 68 ALMAC s.r.l.
E = operating hours with 220Vac electric motor
e = operating hours with 48Vdc electric motor
In the upper part the charge status of the 48V battery is shown.
rC = percentage of battery charge of the remote controller (battery in the
charger)
If there are alarms present, the display will show only the alarm codes.
If there are no alarms at the moment but there were alarms previously (alarms
caused by malfunctions that appear intermittently), the service symbol will
appear on the display:
The control unit can store up to 16 alarms which are shown by pressing the right
button of the hour counter.
These alarms are not cancelled when the machine is turned off.