PAGE 41 ALMAC s.r.l.
No.
Identification
Function and Status
Description of the function
ELECTRIC
ENGINE
position
Powering of electric motor AC
110V or 220V.
To switch on the electric
motor, press the button (1)
located on the left side of the
console.
The electric motor only works
if the plug on the back of the
machine has been connected
to an external power source.
BI-ENERGY
ENGINE
position
Endothermic Engine.
- Activate the glow plug
preheating by keeping the
button (5) pressed for at least
10 sec.
- Press the button (1) located
on the left side of the console
to start the engine
(To switch off the internal
combustion engine, turn the
selector downwards)
ELECTRICA
ENGINE
position
Powering of electric motor DC
48V.
To switch on the electric
motor, press the button (1)
located on the left side of the
console.
3
Emergency
Button
EMERGENCY STOP
4
Selector
MACHINE DYNAMICS POSITION SWITCH
HIGH position
The loading platform remains
always positioned at the
maximum height permitted.
This allows the passing
through openings with a
minimum width of 1.43
meters.
MED position
The loading platform remains
always positioned at an
intermediate height.
LOW position
The loading platform is always
positioned at the minimum
height permitted. This allows
the passing through openings